Tektronix Telescope 1502C Manual de usuario Pagina 59

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 126
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 58
Operator Tutorial
1502C MTDR User Manual
29
50 W impedance plus 9.5 W series resistance. You can check this by putting a
known reference on the end of the cable and measuring its impedance with
ohms-at-cursor. The difference between the actual reading and the expected
reference reading is the series resistance.
O
F
F
O
F
F
O
F
F
O
N
ac
59.5 W
408.000 ft
Ohms-at-Cursor
Readout
Figure 210: Ohms-at-Cursor
7. Turn the
n
o
POSITION control to set the cursor near the beginning of the
cable. In this example, the ohms-at-cursor reading is 50.9 W at 17.880 feet.
There is less loss at the beginning of the cable because there is less series
resistance.
O
F
F
O
F
F
O
F
F
O
N
ac
50.9 W
17.880 ft
Figure 211: Ohms-at-Cursor Near Beginning of Cable
8. Turn the
n
o
POSITION control clockwise to set the cursor past the reflected
pulse. Note that the ohms-at-cursor reading is 1 kW.
Vista de pagina 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 125 126

Comentarios a estos manuales

Sin comentarios