Tektronix Thermometer P6131 Manual de usuario

Busca en linea o descarga Manual de usuario para De medición, control y control Tektronix Thermometer P6131. Tektronix Thermometer P6131 User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Instruction Manual
P6131
10X Passive Probe
for 2400 Series Oscilloscopes
070-5514-03
*P070551403*
070551403
Warning
The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to all safety summaries prior to
performing service.
www.tektronix.com
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - 070-5514-03

Instruction ManualP613110X Passive Probefor 2400 Series Oscilloscopes070-5514-03*P070551403*070551403WarningThe servicing instructions are for use by

Pagina 2

Specifications4P6131 Instruction Manual@25% Duty Factor=(1/2 Peak V) RMS@50% Duty Factor=(1.414 (Peak V)) RMSSpecial case of square wave:@20% Duty Fac

Pagina 3 - WARRANTY

SpecificationsP6131 Instruction Manual5Frequency (MHz)500100101 10 100Voltage(RMS)Figure 4: Typical P6131 voltage derating versus frequencyTable 2: En

Pagina 4 - Contacting Tektronix

Specifications6P6131 Instruction ManualTable 4: Certifications and compliances EC Declaration ofConformityCompliance was demonstrated to the following

Pagina 5 - General Safety Summary

P6131 Instruction Manual7Service InformationWARNING. The following instructions are for use by qualified service personnelonly. To avoid electrical sh

Pagina 6 - Service Safety Summary

Service Information8P6131 Instruction ManualTable 5: Performance verification and adjustment test equipment (cont.)Description Example productMinimum

Pagina 7 - Operating Basics

Service InformationP6131 Instruction Manual94. Adjust the sine wave generator output amplitude to produce a 6-divisiondisplay on the test oscilloscope

Pagina 8 - Grounding the Probe

Service Information10P6131 Instruction Manual6. Remove the coax cable from the test setup. Connect the P6131 probe outputto the same vertical input on

Pagina 9

Service InformationP6131 Instruction Manual11To adjust the probe low-frequency compensation do the following:1. Connect the probe output to the test o

Pagina 10 - (Duty Factor)]

Service Information12P6131 Instruction ManualOver compensatedUnder compensatedCorrectFigure 7: Low-frequency compensation, optimizing the waveformTo a

Pagina 11

Service InformationP6131 Instruction Manual138. Connect the probe output to the oscilloscope vertical input.9. Connect the probe tip through the probe

Pagina 12 - P6131 Instruction Manual

Copyright © Tektronix, Inc. All rights reserved.Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this pu

Pagina 13 - Service Information

Service Information14P6131 Instruction ManualR2010R2020R2021C1010R2010C1010C2010R2021R2020Plastic-shell versionMetal-shell versionFigure 8: High-frequ

Pagina 14 - Bandwidth Check

Service InformationP6131 Instruction Manual15MaintenanceUse the following procedures to clean and maintain the P6131 probe.To remove accumulated dirt

Pagina 15 - Attenuation Accuracy

Service Information16P6131 Instruction Manual

Pagina 16 - Adjustment Procedure

P6131 Instruction Manual17Replaceable PartsThis section contains a list of the replaceable modules for the P6131 probe. Usethis list to identify and o

Pagina 17 - Adjustment

Replaceable Parts18P6131 Instruction ManualUsing the Replaceable Parts ListThis section contains a list of the replaceable mechanical and electrical c

Pagina 18 - High-Frequency

Replaceable PartsP6131 Instruction Manual191234567891011121314151617Figure 10: P6131 probe with standard accessoriesReplaceable parts: P6131 probe and

Pagina 19

Replaceable Parts20P6131 Instruction ManualReplaceable parts: P6131 probe and standard accessories (cont.)Fig. &indexnumberMfr. part numberMfr. co

Pagina 20

Replaceable PartsP6131 Instruction Manual211 2 3 4 5 67 8 9 10 11 121314Figure 11: P6131 probe optional accessoriesReplaceable parts: P6131 probe opti

Pagina 21 - Maintenance

Replaceable Parts22P6131 Instruction ManualReplaceable parts: P6131 probe optional accessories (cont.)Fig. &indexnumberMfr. part numberMfr. codeNa

Pagina 22

WARRANTYTektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanshipfor a period of one

Pagina 23 - Replaceable Parts

Contacting TektronixProductsupportFor questions about using Tektronix measurement products, call toll free in North America:1-800-833–92006:00 a.m. –

Pagina 24 - Cross Index

P6131 Instruction Manual iGeneral Safety SummaryReview the following safety precautions to avoid injury and prevent damage tothis product or any produ

Pagina 25

iiP6131 Instruction ManualService Safety SummaryOnly qualified personnel should perform service procedures. Read this ServiceSafety Summary and the G

Pagina 26

P6131 Instruction Manual1Operating BasicsThe P6131 probe is a subminiature, 10X, passive probe designed specifically foruse with Tektronix 2400 Series

Pagina 27

Operating Basics2P6131 Instruction ManualGrounding the ProbeConnect the probe to the instrument and connect the ground lead to groundbefore making any

Pagina 28 - Manufacturers cross index

P6131 Instruction Manual3SpecificationsThe characteristics listed in Table 1 apply to P6131 probes installed on Tektronix2445 and 2465 oscilloscopes o

Comentarios a estos manuales

Sin comentarios