Tektronix MTM400 Manual de usuario Pagina 100

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 197
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 99
Stream View
3-52 MTM400 MPEG Transport Stream Monitor User Manual
Figure 3-17: Stream view - PCR graph - PCR overall jitter
The Maximum PCR Accuracy Error can be adjusted for all PIDs as follows:
Tests screen Î PCR Tests section Î PCR Overall Jitter (PCR_OJ)
parameter (right-click) Î Max PCR overall jitter.
For individual PIDs:
PIDs screen Î Test: select PCR Jitter Î individual PID parameter (right-
click) Î Max PCR overall jitter.
Right-click on the graph and set the limit for each PID.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - FAX 781.665.0780 - TestEquipmentDepot.com
Vista de pagina 99
1 2 ... 95 96 97 98 99 100 101 102 103 104 105 ... 196 197

Comentarios a estos manuales

Sin comentarios