User ManualCTS 710SONET Test Set070-8852-03This document applies to firmware version 1.3and above.User ManualCTS 710SONET Test Set070-8852-03This docu

Pagina 2

Table of ContentsviCTS 710 SONET Test Set User ManualViewing Detailed Results 3–174. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Displayin

Pagina 3 - WARRANTY

Basic Test Procedures3–10CTS 710 SONET Test Set User Manual2. To check the LTE response to a Section B1 error, set up theupstream CTS 710 as follows:P

Pagina 4

Basic Test ProceduresCTS 710 SONET Test Set User Manual3–113. Set up the downstream CTS 710 as follows:Press MenuButtonSelect MenuPageHighlightParamet

Pagina 5 - Table of Contents

Basic Test Procedures3–12CTS 710 SONET Test Set User Manual9. Change the downstream CTS 710 as follows:Press MenuButtonSelect MenuPageHighlightParamet

Pagina 6 - Reference

Basic Test ProceduresCTS 710 SONET Test Set User Manual3–1315. Change the downstream CTS 710 as follows:Press MenuButtonSelect MenuPageHighlightParame

Pagina 7

Basic Test Procedures3–14CTS 710 SONET Test Set User ManualNECTS 710 SONET Test SetAll Signals areSTS-3Figure 3–5: Setup to Check Pointer MovementsBas

Pagina 8

Basic Test ProceduresCTS 710 SONET Test Set User Manual3–152. Set up the CTS 710 as follows:Press MenuButtonSelect MenuPageHighlightParameterSelect Ch

Pagina 9

Basic Test Procedures3–16CTS 710 SONET Test Set User ManualResponse to Line Frequency OffsetPointers also accommodate differences in line frequency fr

Pagina 10

Basic Test ProceduresCTS 710 SONET Test Set User Manual3–172. Set up the CTS 710 as follows:Press MenuButtonSelect MenuPageHighlightParameterSelect Ch

Pagina 11 - Appendices

Basic Test Procedures3–18CTS 710 SONET Test Set User ManualPerformance MonitoringWhen a new line is installed you may want to monitor performancefor a

Pagina 12 - Glossary and Index

Basic Test ProceduresCTS 710 SONET Test Set User Manual3–19NENEAll Signals are OC-3CTS 710 SONET Test SetFigure 3–7: Setup to Monitor Performance2. Se

Pagina 13 - List of Figures

Table of ContentsCTS 710 SONET Test Set User ManualviiRunning Instrument Self Tests 3–210. . . . . . . . . . . . . . . . . . . . . . . . . . Running t

Pagina 14

Basic Test Procedures3–20CTS 710 SONET Test Set User ManualPayload errors by pressing the buttons corresponding to thosechoices.5. To see network perf

Pagina 15

Basic Test ProceduresCTS 710 SONET Test Set User Manual3–217. For example, to change the bottom graph to display the history ofPath B3 Errored Seconds

Pagina 16

Basic Test Procedures3–22CTS 710 SONET Test Set User ManualBasic Test Procedures3–22CTS 710 SONET Test Set User Manual

Pagina 17

CTS 710 SONET Test Set User Manual3–23Setting Test Control ParametersThis section describes how to set the duration for a test, theresolution of the t

Pagina 18 - List of Tables

Setting Test Control Parameters3–24CTS 710 SONET Test Set User ManualOnce the test duration is set, any time a test is started it will run forthe time

Pagina 19

Setting Test Control ParametersCTS 710 SONET Test Set User Manual3–25To set a unique test duration:Press MenuButtonSelect MenuPageHighlightParameterSe

Pagina 20

Setting Test Control Parameters3–26CTS 710 SONET Test Set User ManualTable 3–2 lists the range limits for the test duration.Table 3–2: Test Duration L

Pagina 21 - General Safety Summary

Setting Test Control ParametersCTS 710 SONET Test Set User Manual3–27To set the history resolution of a test:Press MenuButtonSelect MenuPageHighlightP

Pagina 22 - Product Damage Precautions

Setting Test Control Parameters3–28CTS 710 SONET Test Set User ManualBar Graph showspercent of test completeElapsed Timesince test startedFigure 3–10:

Pagina 23 - Safety Terms and Symbols

Setting Test Control ParametersCTS 710 SONET Test Set User Manual3–29Table 3–3: Actions You Cannot Perform While a Test is Running MenuPage ActionTEST

Pagina 24

Table of ContentsviiiCTS 710 SONET Test Set User ManualAppendix B: Status and Error Messages B–1. . . . . . . . . . . . . . . . Status Messages B–1. .

Pagina 25 - Conventions

Setting Test Control Parameters3–30CTS 710 SONET Test Set User ManualSetting Test Control Parameters3–30CTS 710 SONET Test Set User Manual

Pagina 26 - Related Manuals

CTS 710 SONET Test Set User Manual3–31Working with Test SetupsThis section describes how to save instrument setups to disk, recallinstrument setups, c

Pagina 27

Working with Test Setups3–32CTS 710 SONET Test Set User ManualSaving Instrument SetupsTo save an instrument setup:1. Set up the CTS 710 as desired. Se

Pagina 28 - Contacting Tektronix

Working with Test SetupsCTS 710 SONET Test Set User Manual3–33Figure 3–11: The SAVE INSTRUMENT SETUPS Page3. Enter a description of the instrument set

Pagina 29

Working with Test Setups3–34CTS 710 SONET Test Set User Manual5. Save the instrument setup to disk as follows:H Insert a disk to store the file on, if

Pagina 30

Working with Test SetupsCTS 710 SONET Test Set User Manual3–35Figure 3–12: The RECALL INSTRUMENT SETUPS PageThe disk file listing displays up to six f

Pagina 31 - Getting Started

Working with Test Setups3–36CTS 710 SONET Test Set User ManualDeleting Instrument Setups from DiskYou can delete instrument setups from disk using the

Pagina 32 - Accessories

Working with Test SetupsCTS 710 SONET Test Set User Manual3–37Pass/Fail TestsA pass/fail test is an easy way to run a test and get a simple responsest

Pagina 33 - First Time Operation

Working with Test Setups3–38CTS 710 SONET Test Set User ManualNOTE. A pass/fail test can only be saved on disk. It cannot be savedin memory.H Descript

Pagina 34

Working with Test SetupsCTS 710 SONET Test Set User Manual3–39H Detected. If the specified condition is detected, the test fails.H Not Detected. If th

Pagina 35 - Velcro Strip

Table of ContentsCTS 710 SONET Test Set User ManualixList of FiguresFigure i: Placing the Reference for Easy Viewing xxiii. . . . . . . . Figure 1–1:

Pagina 36

Working with Test Setups3–40CTS 710 SONET Test Set User ManualTable 3–4: Fail If Conditions of a Pass/Fail Test (Cont.)Condition Type ThresholdSpecifi

Pagina 37

Working with Test SetupsCTS 710 SONET Test Set User Manual3–41Table 3–4: Fail If Conditions of a Pass/Fail Test (Cont.)Condition Type ThresholdSpecifi

Pagina 38

Working with Test Setups3–42CTS 710 SONET Test Set User ManualTable 3–4: Fail If Conditions of a Pass/Fail Test (Cont.)Condition Type ThresholdSpecifi

Pagina 39 - 180–250 V 48–62 Hz 250 W

Working with Test SetupsCTS 710 SONET Test Set User Manual3–43Table 3–4: Fail If Conditions of a Pass/Fail Test (Cont.)Condition Type ThresholdSpecifi

Pagina 40

Working with Test Setups3–44CTS 710 SONET Test Set User ManualTable 3–4: Fail If Conditions of a Pass/Fail Test (Cont.)Condition Type ThresholdSpecifi

Pagina 41

Working with Test SetupsCTS 710 SONET Test Set User Manual3–45number (or letter). Select DONE when you are finishedediting the setup name.H Select EDI

Pagina 42

Working with Test Setups3–46CTS 710 SONET Test Set User Manual4. Enter an operator start prompt as follows:Press MenuButtonSelect MenuPageHighlightPar

Pagina 43 - Functional Overview

Working with Test SetupsCTS 710 SONET Test Set User Manual3–475. Set the test duration as follows:Press MenuButtonSelect MenuPageHighlightParameterSel

Pagina 44

Working with Test Setups3–48CTS 710 SONET Test Set User Manual7. Highlight the first entry in the second column (see Figure 3–15).If you wish to speci

Pagina 45

Working with Test SetupsCTS 710 SONET Test Set User Manual3–4911. Specify the action to be taken when the test completes as follows:Press MenuButtonSe

Pagina 46 - Front-Panel Status Lights

Table of ContentsxCTS 710 SONET Test Set User ManualFigure 2–19: Editing a Text String 2–23. . . . . . . . . . . . . . . . . . . . . Figure 2–20: Setu

Pagina 47

Working with Test Setups3–50CTS 710 SONET Test Set User Manual2. Select the pass/fail test to run as follows:Press MenuButtonSelect MenuPageHighlightP

Pagina 48 - Reading the Display

Working with Test SetupsCTS 710 SONET Test Set User Manual3–51Figure 3–16: The TEST BEGIN Dialog Box3. To run the pass/fail test immediately, press ST

Pagina 49

Working with Test Setups3–52CTS 710 SONET Test Set User ManualTo change an existing pass/fail test:1. Insert the disk containing the pass/fail test in

Pagina 50

Working with Test SetupsCTS 710 SONET Test Set User Manual3–53existing file. To overwrite the file, select Overwrite. If youdo not want to overwrite t

Pagina 51 - The Basic Menu Structure

Working with Test Setups3–54CTS 710 SONET Test Set User ManualWorking with Test Setups3–54CTS 710 SONET Test Set User Manual

Pagina 52

CTS 710 SONET Test Set User Manual3–55Checking Signal StatusThis section describes how to use the CTS 710 to check signal status.The CTS 710 continuou

Pagina 53

Checking Signal Status3–56CTS 710 SONET Test Set User ManualFigure 3–18: The AUTOSCAN Dialog Box Showing Signal StructureViewing the Payload (Add/Drop

Pagina 54 - Displaying Help

Checking Signal StatusCTS 710 SONET Test Set User Manual3–57Figure 3–19: Viewing Tributary Signal StructureDetermining the Payload Pattern and Framing

Pagina 55 - Connecting Signals

Checking Signal Status3–58CTS 710 SONET Test Set User ManualThis shows that an alarm wasdetected in the VT.This means the VT is equipped. That is,the

Pagina 56

Checking Signal StatusCTS 710 SONET Test Set User Manual3–59Clear Historybutton clearshistory of eventsYellow history lightsindicate an event hasoccur

Pagina 57 - Changing Parameters

Table of ContentsCTS 710 SONET Test Set User ManualxiFigure 3–10: Elapsed Time and Bar Graph Indicators 3–28. . . . Figure 3–11: The SAVE INSTRUMENT S

Pagina 58

Checking Signal Status3–60CTS 710 SONET Test Set User ManualH Red lights indicate the associated condition is valid. For example,if the red light next

Pagina 59

Checking Signal StatusCTS 710 SONET Test Set User Manual3–61Extended StatusThe red-yellow pair of ERROR lights on the front panel turn onwhen a variet

Pagina 60

Checking Signal Status3–62CTS 710 SONET Test Set User ManualChecking Signal Status3–62CTS 710 SONET Test Set User Manual

Pagina 61

CTS 710 SONET Test Set User Manual3–63Setting SONET Transmit ParametersThis section describes how to set the transmit rate, specify the STSunder test,

Pagina 62

Setting SDHSONET Transmit Parameters3–64CTS 710 SONET Test Set User ManualSetRateSetClockSet SignalStructureSpecify STSUnder TestSetMappingSet VT Unde

Pagina 63

Setting SDHSONET Transmit ParametersCTS 710 SONET Test Set User Manual3–65rate while simultaneously transmitting an optical signal at the OC-3rate.How

Pagina 64

Setting SDHSONET Transmit Parameters3–66CTS 710 SONET Test Set User ManualTo couple the transmit and receive settings together from theTRANSMIT SETTIN

Pagina 65 - Working with the Disk Drive

Setting SDHSONET Transmit ParametersCTS 710 SONET Test Set User Manual3–67Through ModeUse Through Mode to monitor a signal without changing it. InThro

Pagina 66

Setting SDHSONET Transmit Parameters3–68CTS 710 SONET Test Set User ManualThrough Mode IconFigure 3–25: CTS 710 in Through ModeSetting the Transmit Cl

Pagina 67

Setting SDHSONET Transmit ParametersCTS 710 SONET Test Set User Manual3–69H Select BITS to use the clock signal from an external BITSreference. Attach

Pagina 68

Table of ContentsxiiCTS 710 SONET Test Set User ManualFigure 3–36: Sequence for Setting SONET Signal Parameters 3–99. . . . . . . . . . . . . . . . .

Pagina 69 - Tutorial

Setting SDHSONET Transmit Parameters3–70CTS 710 SONET Test Set User ManualTo specify the structure of an STS-3, OC-3, or OC-12 signal:Press MenuButton

Pagina 70 - Setting Transmit Parameters

Setting SDHSONET Transmit ParametersCTS 710 SONET Test Set User Manual3–71Setting the Payload MappingTo set the payload mapping:Press MenuButtonSelect

Pagina 71

Setting SDHSONET Transmit Parameters3–72CTS 710 SONET Test Set User ManualUnequipped Payload MappingIf you choose Bulk Fill No Mapping (Unequipped) pa

Pagina 72 - Setting Receive Parameters

Setting SDHSONET Transmit ParametersCTS 710 SONET Test Set User Manual3–73Figure 3–26: Mapping a Tributary SignalTo configure the CTS 710 for mapping

Pagina 73 - Setting the Test Time

Setting SDHSONET Transmit Parameters3–74CTS 710 SONET Test Set User Manual2. If the Mapping is set to VT1.5 specify the VT under test asfollows:Press

Pagina 74 - RESULTS none none none

Setting SDHSONET Transmit ParametersCTS 710 SONET Test Set User Manual3–75H Select DS3 Ext Add to map a DS3 signal, connected to theDS3 Input connecto

Pagina 75 - Begin the Test

Setting SDHSONET Transmit Parameters3–76CTS 710 SONET Test Set User ManualIf you select User Word 8 bit/16 bit/24 bit for the test pattern, set theval

Pagina 76 - Inserting Errors

Setting SDHSONET Transmit ParametersCTS 710 SONET Test Set User Manual3–77Figure 3–27: Editing the User Word ByteSetting Overhead BytesTo stress test

Pagina 77 - Error type set to Path B3 BIP

Setting SDHSONET Transmit Parameters3–78CTS 710 SONET Test Set User ManualTo edit overhead bytes:1. Display the transport overhead as follows:Press Me

Pagina 78 - Adjusting Pointers

Setting SDHSONET Transmit ParametersCTS 710 SONET Test Set User Manual3–79Z2 byteselected toeditBytes you cannever editCannot editbecausealarm is setF

Pagina 79

Table of ContentsCTS 710 SONET Test Set User ManualxiiiFigure 3–59: Line Graph Showing Pointer Value 3–184. . . . . . . . . Figure 3–60: On/Off Graphs

Pagina 80

Setting SDHSONET Transmit Parameters3–80CTS 710 SONET Test Set User ManualH Define your own byte with the buttons next to 1 and 0. Usethe left and rig

Pagina 81 - USER DEFINED

Setting SDHSONET Transmit ParametersCTS 710 SONET Test Set User Manual3–81Table 3–7: Choices for Bits 5, 6, and 7 of the V5 Byte ChoiceUnequip (000)Eq

Pagina 82 - Viewing Transport Overhead

Setting SDHSONET Transmit Parameters3–82CTS 710 SONET Test Set User ManualThe bytes that cannot be edited are marked with a line of asterisks onthe TR

Pagina 83

Setting SDHSONET Transmit ParametersCTS 710 SONET Test Set User Manual3–83consisting of ASCII characters (rather than the ones and zeros usedto edit t

Pagina 84

Setting SDHSONET Transmit Parameters3–84CTS 710 SONET Test Set User ManualThe string can contain a maximum of 64 characters, includingspaces.3. Select

Pagina 85 - Viewing Test Results

Setting SDHSONET Transmit ParametersCTS 710 SONET Test Set User Manual3–852. To configure the CTS 710 to add the external data bytes:Press MenuButtonS

Pagina 86 - MAIN RESULTS none none

Setting SDHSONET Transmit Parameters3–86CTS 710 SONET Test Set User ManualFigure 3–31: Adding Data into the DCCTo add external data into the User Chan

Pagina 87

Setting SDHSONET Transmit ParametersCTS 710 SONET Test Set User Manual3–87Figure 3–32: Adding Data into the User ChannelSetting SDHSONET Transmit Para

Pagina 88

Setting SDHSONET Transmit Parameters3–88CTS 710 SONET Test Set User ManualSetting SDHSONET Transmit Parameters3–88CTS 710 SONET Test Set User Manual

Pagina 89 - Reference Reference

CTS 710 SONET Test Set User Manual3–89Setting Tributary Signal TransmitParametersThis section describes how to set the transmit rate, transmit clock,l

Pagina 90

Table of ContentsxivCTS 710 SONET Test Set User ManualList of TablesTable 1–1: Fuse and Fuse Cap Part Numbers 1–8. . . . . . . . . . . Table 1–2: Pow

Pagina 91 - Basic Test Procedures

Setting Tributary SignalPDH Transmit Parameters3–90CTS 710 SONET Test Set User ManualSetting the Transmit RateTo set the transmit rate:Press MenuButto

Pagina 92 - Network Continuity Checking

Setting Tributary SignalPDH Transmit ParametersCTS 710 SONET Test Set User Manual3–91After they are coupled, any change you make to a parameter on the

Pagina 93

Setting Tributary SignalPDH Transmit Parameters3–92CTS 710 SONET Test Set User ManualNOTE. When settings are coupled from the TRANSMIT SETTINGSpage, t

Pagina 94

Setting Tributary SignalPDH Transmit ParametersCTS 710 SONET Test Set User Manual3–93H Select Recovered to use the clock recovered from an incomingsig

Pagina 95

Setting Tributary SignalPDH Transmit Parameters3–94CTS 710 SONET Test Set User ManualH Select AMI to set the line code to Alternate Mark Inversion.H S

Pagina 96 - Save to Disk Save Current

Setting Tributary SignalPDH Transmit ParametersCTS 710 SONET Test Set User Manual3–95H Select DS1 ESF to transmit a signal with Extended Superframefra

Pagina 97

Setting Tributary SignalPDH Transmit Parameters3–96CTS 710 SONET Test Set User ManualSpecifying the Test PatternYou can select a test pattern to trans

Pagina 98 - Fault Tolerance Checking

Setting Tributary SignalPDH Transmit ParametersCTS 710 SONET Test Set User Manual3–97If you select User Word 8 bit/16 bit/24 bit for the test pattern,

Pagina 99

Setting Tributary SignalPDH Transmit Parameters3–98CTS 710 SONET Test Set User ManualSetting Tributary SignalPDH Transmit Parameters3–98CTS 710 SONET

Pagina 100

CTS 710 SONET Test Set User Manual3–99Setting SONET Receive ParametersThis section describes how to manually set the receive line rate,define the STS

Pagina 101

Table of ContentsCTS 710 SONET Test Set User ManualxvTable 3–20: Choices for Bit 5 of the K2 Byte When Mode is Set to Span 3–169. . . . . . . . . . .

Pagina 102

Setting SONETSDH Receive Parameters3–100CTS 710 SONET Test Set User ManualSetRateSet Level(STS Ratesonly)Set SignalStructureSpecify STSUnder TestSetMa

Pagina 103

Setting SONETSDH Receive ParametersCTS 710 SONET Test Set User Manual3–101Available SONETReceive RatesFigure 3–38: SONET Receive RatesIndependent Rece

Pagina 104

Setting SONETSDH Receive Parameters3–102CTS 710 SONET Test Set User ManualRECEIVE SETTINGS page will also be made to the correspondingsetting in the T

Pagina 105

Setting SONETSDH Receive ParametersCTS 710 SONET Test Set User Manual3–103NOTE. When the incoming line rate changes, a valid LOS must occurbetween the

Pagina 106

Setting SONETSDH Receive Parameters3–104CTS 710 SONET Test Set User ManualTo specify the structure of a received STS-3, OC-3, or OC-12 signal:Press Me

Pagina 107

Setting SONETSDH Receive ParametersCTS 710 SONET Test Set User Manual3–105To specify the mapping of the received signal:Press MenuButtonSelect MenuPag

Pagina 108 - Performance Monitoring

Setting SONETSDH Receive Parameters3–106CTS 710 SONET Test Set User ManualNOTE. The CTS 710 will report errors incorrectly when the receivemapping is

Pagina 109

Setting SONETSDH Receive ParametersCTS 710 SONET Test Set User Manual3–107Demultiplexing a DS1 from a DS3 Mapped in a SONETSignal (Add/Drop/Test Optio

Pagina 110

Setting SONETSDH Receive Parameters3–108CTS 710 SONET Test Set User Manual3. Specify the DS1 Framing as follows:Press MenuButtonSelect MenuPageHighlig

Pagina 111

Setting SONETSDH Receive ParametersCTS 710 SONET Test Set User Manual3–1095. Specify the received test pattern as follows:Press MenuButtonSelect MenuP

Pagina 112

Copyright E Tektronix, Inc. 1994. All rights reserved.Tektronix products are covered by U.S. and foreign patents, issued andpending. Information in th

Pagina 113

Table of ContentsxviCTS 710 SONET Test Set User ManualTable D–3: Environmental Specifications D–17. . . . . . . . . . . . . . Table D–4: Physical Cha

Pagina 114

Setting SONETSDH Receive Parameters3–110CTS 710 SONET Test Set User ManualDemapping a Tributary Signal (Add/Drop/Test Option Only)To demap and test a

Pagina 115

Setting SONETSDH Receive ParametersCTS 710 SONET Test Set User Manual3–111H Select VT #1 to specify the first virtual tributary.H Select VT #28 to spe

Pagina 116

Setting SONETSDH Receive Parameters3–112CTS 710 SONET Test Set User ManualTo turn on Tributary Drop:Press MenuButtonSelect MenuPageHighlightParameterS

Pagina 117 - Starting and Stopping a Test

Setting SONETSDH Receive ParametersCTS 710 SONET Test Set User Manual3–113Setting the Test PatternTo specify the test pattern that will be received:1.

Pagina 118

Setting SONETSDH Receive Parameters3–114CTS 710 SONET Test Set User ManualUnequipped Payload MappingIf you choose Bulk Fill No Mapping (Unequipped) pa

Pagina 119

Setting SONETSDH Receive ParametersCTS 710 SONET Test Set User Manual3–115Figure 3–40: Displaying Received Optical PowerViewing Overhead BytesThis sec

Pagina 120

Setting SONETSDH Receive Parameters3–116CTS 710 SONET Test Set User Manual2. Select the columns you wish to display as follows:Press MenuButtonSelect

Pagina 121 - Working with Test Setups

Setting SONETSDH Receive ParametersCTS 710 SONET Test Set User Manual3–117Displaying the V5 ByteTo view the V5 byte:Press MenuButtonSelect MenuPageHig

Pagina 122

Setting SONETSDH Receive Parameters3–118CTS 710 SONET Test Set User Manual2. Configure the CTS 710 to drop the DCC data bytes:Press MenuButtonSelect M

Pagina 123 - Save to Memory Memory n

Setting SONETSDH Receive ParametersCTS 710 SONET Test Set User Manual3–119To drop data from the User Channel:1. Connect an external protocol analyzer

Pagina 124

CTS 710 SONET Test Set User ManualxviiGeneral Safety SummaryReview the following safety precautions to avoid injury and preventdamage to this product

Pagina 125

Setting SONETSDH Receive Parameters3–120CTS 710 SONET Test Set User ManualControlling the Display UpdateTo pause or continue overhead byte updating:Pr

Pagina 126

CTS 710 SONET Test Set User Manual3–121Setting Tributary Receive ParametersThis section describes how to manually set the receive rate, receivelevel,

Pagina 127 - Pass/Fail Tests

Setting TributaryPDH Receive Parameters3–122CTS 710 SONET Test Set User ManualSetting the Receive RateTo set the receive rate:Press MenuButtonSelect M

Pagina 128

Setting TributaryPDH Receive ParametersCTS 710 SONET Test Set User Manual3–123Independent Receive and Transmit SettingsGenerally, you can set the rece

Pagina 129

Setting TributaryPDH Receive Parameters3–124CTS 710 SONET Test Set User ManualTo change receive and transmit settings so that they are no longercouple

Pagina 130

Setting TributaryPDH Receive ParametersCTS 710 SONET Test Set User Manual3–125To specify the framing of a received tributary signal:Press MenuButtonSe

Pagina 131

Setting TributaryPDH Receive Parameters3–126CTS 710 SONET Test Set User ManualH Select 1 in 8 to set the test pattern to 1000 0000.H Select User Word

Pagina 132

Setting TributaryPDH Receive ParametersCTS 710 SONET Test Set User Manual3–127Demultiplexing a DS1 from a DS3 SignalTo demultiplex a DS1 signal from a

Pagina 133

Setting TributaryPDH Receive Parameters3–128CTS 710 SONET Test Set User Manual3. Specify the DS1 Framing as follows:Press MenuButtonSelect MenuPageHig

Pagina 134 - Creating a Pass/Fail Test

Setting TributaryPDH Receive ParametersCTS 710 SONET Test Set User Manual3–1294. Specify the received test pattern as follows:Press MenuButtonSelect M

Pagina 135

General Safety SummaryxviiiCTS 710 SONET Test Set User ManualDo Not Operate in Wet/Damp ConditionsTo avoid electric shock, do not operate this product

Pagina 136

Setting TributaryPDH Receive Parameters3–130CTS 710 SONET Test Set User ManualSetting TributaryPDH Receive Parameters3–130CTS 710 SONET Test Set User

Pagina 137

CTS 710 SONET Test Set User Manual3–131Setting Alarms and Inserting ErrorsThis section describes how to simulate error conditions, set alarms,and simu

Pagina 138

Setting Alarms and Inserting Errors3–132CTS 710 SONET Test Set User ManualSpecifying the Error to InsertSpecify the type of error transmitted as follo

Pagina 139

Setting Alarms and Inserting ErrorsCTS 710 SONET Test Set User Manual3–133Inserting ErrorsYou can choose to insert errors manually (one at a time) or

Pagina 140

Setting Alarms and Inserting Errors3–134CTS 710 SONET Test Set User ManualTable 3–11: Maximum Error Rates for SONET Signals Error TypeRate:StructureSe

Pagina 141

Setting Alarms and Inserting ErrorsCTS 710 SONET Test Set User Manual3–135NOTE. The CTS 710 can measure all the error rates it can transmitexcept for

Pagina 142

Setting Alarms and Inserting Errors3–136CTS 710 SONET Test Set User ManualTo transmit an alarm:Press MenuButtonSelect MenuPageHighlightParameterSelect

Pagina 143

Setting Alarms and Inserting ErrorsCTS 710 SONET Test Set User Manual3–137H Select VT FERF to transmit a VT FERF alarm.H Select DSn Yellow to transmit

Pagina 144

Setting Alarms and Inserting Errors3–138CTS 710 SONET Test Set User ManualSimulating Transmit FailuresThe CTS 710 can simulate transmit failure condit

Pagina 145 - Checking Signal Status

Setting Alarms and Inserting ErrorsCTS 710 SONET Test Set User Manual3–139All transmit failures remain in effect until they are deliberatelyturned off

Pagina 146

General Safety SummaryCTS 710 SONET Test Set User ManualxixSafety Terms and SymbolsTerms in This ManualThese terms may appear in this manual:WARNING.

Pagina 147

Setting Alarms and Inserting Errors3–140CTS 710 SONET Test Set User ManualSetting Alarms and Inserting Errors3–140CTS 710 SONET Test Set User Manual

Pagina 148 - Viewing the Signal State

CTS 710 SONET Test Set User Manual3–141Setting Pointers and Changing TimingThis section describes how to generate pointer movements within thetransmit

Pagina 149

Setting Pointers and Changing Timing3–142CTS 710 SONET Test Set User Manual2. Specify the pointer type as follows:Press MenuButtonSelect MenuPageHighl

Pagina 150

Setting Pointers and Changing TimingCTS 710 SONET Test Set User Manual3–143by one location. The first press increments the pointer, the secondpress de

Pagina 151

Setting Pointers and Changing Timing3–144CTS 710 SONET Test Set User Manual500 ms,NominalIncrementNext Two Presses of POINTERACTIONFirst Press ofPOINT

Pagina 152

Setting Pointers and Changing TimingCTS 710 SONET Test Set User Manual3–145H Select Max 782 to set the pointer to location 782 (points to thebyte imme

Pagina 153 - Steps for Setting Parameters

Setting Pointers and Changing Timing3–146CTS 710 SONET Test Set User ManualH Select Min 0 to set the pointer to location zero. If you choose thissetti

Pagina 154 - Setting the Transmit Rate

Setting Pointers and Changing TimingCTS 710 SONET Test Set User Manual3–147Continuous Pointer MovementTo make repetitive pointer movements:1. Specify

Pagina 155 - Transmit rates

Setting Pointers and Changing Timing3–148CTS 710 SONET Test Set User Manual3. Specify the pointer movement direction as follows:Press MenuButtonSelect

Pagina 156

Setting Pointers and Changing TimingCTS 710 SONET Test Set User Manual3–149Figure 3–50: Incrementing Pointer Location Once Every Two Millisec-ondsChan

Pagina 157

General Safety SummaryxxCTS 710 SONET Test Set User ManualCertifications and CompliancesCSA Certified Power CordsCSA Certification includes the produc

Pagina 158 - Setting the Transmit Clock

Setting Pointers and Changing Timing3–150CTS 710 SONET Test Set User Manual2. Specify the Offset Mode as follows:Press MenuButtonSelect MenuPageHighli

Pagina 159 - Setting the Signal Structure

Setting Pointers and Changing TimingCTS 710 SONET Test Set User Manual3–151Selecting USER DEFINED places the CTS 710 in Edit Mode.The knob is assigned

Pagina 160 - Specifying the STS to Test

Setting Pointers and Changing Timing3–152CTS 710 SONET Test Set User ManualAdded or Cancelled Pointer PositionsRepeating Pattern Time 30 sInitializat

Pagina 161 - Setting the Payload Mapping

Setting Pointers and Changing TimingCTS 710 SONET Test Set User Manual3–153Pointer AdjustmentStart of Next87–3 Pattern87–3 Pattern. . .87No PointerAdj

Pagina 162

Setting Pointers and Changing Timing3–154CTS 710 SONET Test Set User ManualTable 3–13: Pointer Sequences Generated (Cont.)Pointer SequenceDescriptionP

Pagina 163

Setting Pointers and Changing TimingCTS 710 SONET Test Set User Manual3–155Table 3–13: Pointer Sequences Generated (Cont.)Pointer SequenceDescriptionP

Pagina 164

Setting Pointers and Changing Timing3–156CTS 710 SONET Test Set User ManualTable 3–14: Availability of Pointer Sequences (Cont.)Pointer SequenceMappin

Pagina 165 - Setting the Test Pattern

Setting Pointers and Changing TimingCTS 710 SONET Test Set User Manual3–1572. Specify the pointer type as follows:Press MenuButtonSelect MenuPageHighl

Pagina 166

Setting Pointers and Changing Timing3–158CTS 710 SONET Test Set User Manual5. If Sequence Type is set to one of the continuous patterns, set thepointe

Pagina 167 - Setting Overhead Bytes

Setting Pointers and Changing TimingCTS 710 SONET Test Set User Manual3–1597. Specify whether Cool Down Time is included as part of thepointer sequenc

Pagina 168

CTS 710 SONET Test Set User ManualxxiPrefaceThis manual describes how to use the Tektronix CTS 710 SONETTest Set. This manual is your primary source o

Pagina 169 - EDIT BYTE

Setting Pointers and Changing Timing3–160CTS 710 SONET Test Set User ManualFigure 3–54: Status Display While Pointer Sequences are RunningTable 3–15:

Pagina 170

CTS 710 SONET Test Set User Manual3–161Testing Automatic Protection SwitchingThis section describes how to generate Automatic ProtectionSwitching (APS

Pagina 171

Testing Automatic Protection Switching3–162CTS 710 SONET Test Set User ManualFigure 3–55: The APS COMMANDS PageSetting the K1 ByteThere are two ways t

Pagina 172

Testing Automatic Protection SwitchingCTS 710 SONET Test Set User Manual3–163H Select EDIT BYTE to set the byte to a pattern different than thepreset

Pagina 173

Testing Automatic Protection Switching3–164CTS 710 SONET Test Set User ManualTable 3–16: Choices for Bits 1–4 of the K1 Byte When Mode is Set toRing (

Pagina 174

Testing Automatic Protection SwitchingCTS 710 SONET Test Set User Manual3–165Table 3–17: Choices for Bits 1–4 of the K1 Byte When Mode is Set toSpan (

Pagina 175

Testing Automatic Protection Switching3–166CTS 710 SONET Test Set User ManualSee Table 3–18 for descriptions of the preset choices.Table 3–18: Choices

Pagina 176

Testing Automatic Protection SwitchingCTS 710 SONET Test Set User Manual3–167To set the bit pattern of the K2 byte one bit at a time:Press MenuButtonS

Pagina 177

Testing Automatic Protection Switching3–168CTS 710 SONET Test Set User ManualSee Table 3–19 for descriptions of the preset choices.Table 3–19: Choices

Pagina 178

Testing Automatic Protection SwitchingCTS 710 SONET Test Set User Manual3–169The label for Bit 5, of the K2 byte, is Architecture when the mode isset

Pagina 179 - Parameters

PrefacexxiiCTS 710 SONET Test Set User ManualThe Tutorial and the Reference sections frequently presentprocedures in tables. Perform the procedure by

Pagina 180

Testing Automatic Protection Switching3–170CTS 710 SONET Test Set User ManualThe label for Bits 6–8, of the K2 byte, is Status whether the mode isset

Pagina 181 - Available tributary

Testing Automatic Protection SwitchingCTS 710 SONET Test Set User Manual3–171NOTE. You can edit the transmitted K1 and K2 bytes directly from theTRANS

Pagina 182

Testing Automatic Protection Switching3–172CTS 710 SONET Test Set User ManualViewing the Network Response to APS CommandsTo view the network response

Pagina 183 - Setting the Line Clock Offset

CTS 710 SONET Test Set User Manual3–173Viewing ResultsThis section describes how to view, save, recall, and print test results.You can look at test re

Pagina 184 - Specifying the Framing

Viewing Results3–174CTS 710 SONET Test Set User ManualFigure 3–57: The Test Summary PageViewing Detailed ResultsYou can view results either as a summa

Pagina 185

Viewing ResultsCTS 710 SONET Test Set User Manual3–175Displaying an Overview of Test ResultsTo display an overview of test results:Press MenuButtonSel

Pagina 186 - Specifying the Test Pattern

Viewing Results3–176CTS 710 SONET Test Set User ManualTable 3–23: Results Displayed on MAIN RESULTS Page (Cont.)Category Error DisplayedLoss of Frame

Pagina 187

Viewing ResultsCTS 710 SONET Test Set User Manual3–177The Errors category of the MAIN RESULTS page displays results inthree ways. The first way displa

Pagina 188

Viewing Results3–178CTS 710 SONET Test Set User ManualTable 3–24: T1M1 Section Analysis Results Displayed on the ERRORANALYSIS Page CategoryType Anal

Pagina 189

Viewing ResultsCTS 710 SONET Test Set User Manual3–179 Table 3–26: T1M1 Path Analysis Results Displayed on the ERRORANALYSIS Page CategoryType Analysi

Pagina 190 - Setting the Receive Rate

PrefaceCTS 710 SONET Test Set User ManualxxiiiUsing the CTS 710 ReferenceThe Reference presents an overview of the CTS 710 menu structure,front-panel

Pagina 191 - Receive Rates

Viewing Results3–180CTS 710 SONET Test Set User ManualTable 3–27: T1M1 VT1.5 Analysis Results Displayed on the ERRORANALYSIS Page (Cont.)Category Anal

Pagina 192

Viewing ResultsCTS 710 SONET Test Set User Manual3–181Table 3–29: DS1 Path Analysis Results Displayed on ERRORANALYSIS Page Category Type Analysis Res

Pagina 193 - Setting the Receive Level

Viewing Results3–182CTS 710 SONET Test Set User Manualof a graph depends on what is displayed, but the horizontal axisalways displays time.To display

Pagina 194 - Setting the Mapping

Viewing ResultsCTS 710 SONET Test Set User Manual3–183Table 3–31: Measurements Displayed as Bar Graphs MeasurementSection B1 Error CountsSection B1 Er

Pagina 195

Viewing Results3–184CTS 710 SONET Test Set User ManualFigure 3–59: Line Graph Showing Pointer ValueTable 3–32: Measurements Displayed as a Line Graph

Pagina 196

Viewing ResultsCTS 710 SONET Test Set User Manual3–185Figure 3–60: On/Off Graphs Showing Failures and AlarmsTable 3–33: Measurements Displayed as On/O

Pagina 197

Viewing Results3–186CTS 710 SONET Test Set User ManualTable 3–33: Measurements Displayed as On/Off Graphs for SONETRates (Cont.)Graph Type Displayed V

Pagina 198

Viewing ResultsCTS 710 SONET Test Set User Manual3–187Power Out IndicatorIf the power to the CTS 710 fails while a test is running, theCTS 710 display

Pagina 199

Viewing Results3–188CTS 710 SONET Test Set User ManualCursor positionGraph nameCursorMeasurementresults atcursor positionCross-hatchmeans the testwas

Pagina 200

Viewing ResultsCTS 710 SONET Test Set User Manual3–189Table 3–35: Time Represented by Bars on History Graph (Cont.)History Resolution = Normal (1 min

Pagina 201 - Dropping a Tributary Signal

PrefacexxivCTS 710 SONET Test Set User ManualContacting TektronixProductSupportFor application-oriented questions about a Tektronixmeasurement product

Pagina 202

Viewing Results3–190CTS 710 SONET Test Set User ManualPanning History GraphsYou can display different portions of a history graph by panning thegraph.

Pagina 203

Viewing ResultsCTS 710 SONET Test Set User Manual3–191H Select Change Bottom to select a different graph for display onthe bottom half of the screen.H

Pagina 204

Viewing Results3–192CTS 710 SONET Test Set User ManualSaving and Recalling ResultsYou can save test results to disk and recall the test results for la

Pagina 205 - Viewing Overhead Bytes

Viewing ResultsCTS 710 SONET Test Set User Manual3–193H Select EDIT NAME to enter a name other than RESLT_XXfor the pass/fail test. Select DONE when y

Pagina 206

Viewing Results3–194CTS 710 SONET Test Set User Manual3. Save the test results to disk as follows:Press MenuButtonSelect MenuPageHighlightParameterSel

Pagina 207

Viewing ResultsCTS 710 SONET Test Set User Manual3–195the page. The Results Source line will display the name of the filerecalled.Figure 3–64: The REC

Pagina 208

Viewing Results3–196CTS 710 SONET Test Set User ManualRecalling Test Results from MemoryTo recall test results from memory:Press MenuButtonSelect Menu

Pagina 209

Viewing ResultsCTS 710 SONET Test Set User Manual3–197To print the results of the current test:Press MenuButtonSelect MenuPageHighlightParameterSelect

Pagina 210

Viewing Results3–198CTS 710 SONET Test Set User ManualTo print the results of a test saved on disk, recall the results (seepage 3–194) and then print

Pagina 211

CTS 710 SONET Test Set User Manual3–199Changing Instrument SettingsThis section describes how to change the date and time settings,printer settings, a

Pagina 212

Getting Started Getting Started

Pagina 213

Changing Instrument Settings3–200CTS 710 SONET Test Set User ManualTable 3–36: Lines of the Instrument Configuration Page (Cont.)Line DescriptionInter

Pagina 214 - Setting the Framing

Changing Instrument SettingsCTS 710 SONET Test Set User Manual3–201Figure 3–66: The MISC SETTINGS PageTurning the Beeper On and OffThe CTS 710 has a b

Pagina 215

Changing Instrument Settings3–202CTS 710 SONET Test Set User ManualSetting the DateThe date is used when writing files to disk, it is used to trackmea

Pagina 216

Changing Instrument SettingsCTS 710 SONET Test Set User Manual3–203NOTE. While you set the time in Edit Mode, the clock stops running.2. Assign the kn

Pagina 217

Changing Instrument Settings3–204CTS 710 SONET Test Set User Manualyou can specify two lines of text to be included on any printout. Thetwo lines of t

Pagina 218

Changing Instrument SettingsCTS 710 SONET Test Set User Manual3–205To set the RS-232 parameters for the printer:Press MenuButtonSelect MenuPageHighlig

Pagina 219

Changing Instrument Settings3–206CTS 710 SONET Test Set User ManualSetting the Print User & Company TextYou can have the CTS 710 include text on a

Pagina 220

Changing Instrument SettingsCTS 710 SONET Test Set User Manual3–207Setting the GPIB AddressTo set the CTS 710 GPIB address:Press MenuButtonSelect Menu

Pagina 221 - Simulating Error Conditions

Changing Instrument Settings3–208CTS 710 SONET Test Set User ManualFigure 3–68: The REMOTE CONTROL PageSetting RS-232 ParametersThe appropriate settin

Pagina 222

Changing Instrument SettingsCTS 710 SONET Test Set User Manual3–209To set the remote control RS-232 parameters:Press MenuButtonSelect MenuPageHighligh

Pagina 223

WARRANTYTektronix warrants that this product will be free from defects in materials andworkmanship for a period of three (3) years from the date of sh

Pagina 225 - Setting Alarms

Changing Instrument Settings3–210CTS 710 SONET Test Set User ManualPress MenuButtonSelect ChoiceHighlightParameterSelect MenuPageTx Terminator LFCRCR/

Pagina 226

Changing Instrument SettingsCTS 710 SONET Test Set User Manual3–211Running the Power Up Self TestTo run the power up self test:Press MenuButtonSelect

Pagina 227

Changing Instrument Settings3–212CTS 710 SONET Test Set User ManualChanging Instrument Settings3–212CTS 710 SONET Test Set User Manual

Pagina 230

CTS 710 SONET Test Set User ManualA–1Appendix A: Menu MapsTest DurationHistory ResolutionTEST CONTROL Page5 min15 min1 hourContinuousUSERDEFINEDNormal

Pagina 231 - Setting Pointers

Menu MapsA–2CTS 710 SONET Test Set User ManualDiskChoices depend on disk contentRECALL PASS/FAIL TESTS PageRecall &Run TestDelete FileNameDescript

Pagina 232

Menu MapsCTS 710 SONET Test Set User ManualA–3NameDescriptionOperator Start PromptTest DurationFail IfOperator End PromptOn Test CompletionSave to Dis

Pagina 233

Menu MapsA–4CTS 710 SONET Test Set User Manual(Structure=3 x STS-1)123(Rate=STS-3/OC-3)3 x STS-11 x STS-3cTransmit RateTransmit ClockTransmit LevelSig

Pagina 234

Menu MapsCTS 710 SONET Test Set User ManualA–5(Mapping=VT1.5 Async)PRBS2^23–1PRBS2^20–1PRBS2^15–1QRSS2^20–1All OnesAll Zeros1 in 83 in 24User Word8 bi

Pagina 235

CTS 710 SONET Test Set User Manual1–1Getting StartedThis section provides a description of the CTS 710, a list of standardand optional accessories, an

Pagina 236

Menu MapsA–6CTS 710 SONET Test Set User ManualError Type set toError Rate set toTransmit Alarm set toTransmit Failure set toERRORS & ALARMS Page (

Pagina 237

Menu MapsCTS 710 SONET Test Set User ManualA–7Error Type set toError Rate set toTransmit Alarm set toTransmit Failure set toERRORS & ALARMS Page (

Pagina 238

Menu MapsA–8CTS 710 SONET Test Set User ManualError Type set toError Rate set toTransmit Alarm set toTransmit Failure set toERRORS & ALARMS Page (

Pagina 239 - Changing Timing

Menu MapsCTS 710 SONET Test Set User ManualA–9Error Type set toError Rate set toTransmit Alarm set toTransmit Failure set toERRORS & ALARMS Page (

Pagina 240

Menu MapsA–10CTS 710 SONET Test Set User ManualPointer/Timing ModeOffset ModeFrequency OffsetPointer TypeSequence TypePointer ControlPointer Value Set

Pagina 241 - Generating Pointer Sequences

Menu MapsCTS 710 SONET Test Set User ManualA–11Pointer/Timing ModeOffset ModeFrequency OffsetPointer TypeSequence TypePointer ControlPointer Value Set

Pagina 242

Menu MapsA–12CTS 710 SONET Test Set User ManualPointer/Timing ModeOffset ModeFrequency OffsetPointer TypeSequence TypePointer ControlPointer Value Set

Pagina 243

Menu MapsCTS 710 SONET Test Set User ManualA–13APS ModeK1 Full ByteBits 1–4:Bits 5–8:K2 Full ByteBits 1–4:Bit 5:Bits 6–8:Transmit SetupAPS COMMANDS Pa

Pagina 244

Menu MapsA–14CTS 710 SONET Test Set User ManualAPS ModeK1 Full ByteBits 1–4:Bits 5–8:K2 Full ByteBits 1–4:Bit 5:Bits 6–8:Transmit SetupAPS COMMANDS Pa

Pagina 245

Menu MapsCTS 710 SONET Test Set User ManualA–15APS ModeK1 Full ByteBits 1–4:Bits 5–8:K2 Full ByteBits 1–4:Bit 5:Bits 6–8:Transmit SetupAPS COMMANDS Pa

Pagina 246

Getting Started1–2CTS 710 SONET Test Set User ManualThe CTS 710 meets the needs of the craftsperson and the networkengineer. The CTS 710 meets the req

Pagina 247

Menu MapsA–16CTS 710 SONET Test Set User ManualResetOverheadSet to10101010Set to11111111DefaultxxxxxxxxEDIT BYTEShowing Overhead forExternal AddTRANSP

Pagina 248

Menu MapsCTS 710 SONET Test Set User ManualA–17Overhead ViewExternal Add(Overhead View=STS Path Overhead)J1C2F2Z3Z4Z5(Overhead View=V5 Byte)V5PATH OVE

Pagina 249 - Cool Down Time On

Menu MapsA–18CTS 710 SONET Test Set User Manual(Rate=STS-1/STS-3)CrossConnectLow(Rate=DS3)NormalMonitor(Rate=DS1)NormalMonitorBridgeReceive RateReceiv

Pagina 250

Menu MapsCTS 710 SONET Test Set User ManualA–19(Mapping=No Mapping)PRBS2^23–1PRBS2^20–1PRBS2^15–1PRBS2^09–1All OnesAll ZerosUser WordUnknown(Mapping=V

Pagina 251 - Setting the APS Mode

Menu MapsA–20CTS 710 SONET Test Set User ManualExpected Receive RateReceived Optical PowerReceived Peak VoltageSIGNAL STATUS PageA1 A2 C1B1 E1 F1D1 D2

Pagina 252 - Setting the K1 Byte

Menu MapsCTS 710 SONET Test Set User ManualA–21Overhead ViewExternal DropPause Control(Overhead View=STS Path Overhead)J1B3C2G1F2H4Z3Z4Z5(Overhead Vie

Pagina 253

Menu MapsA–22CTS 710 SONET Test Set User ManualErrorsFailuresAlarmsPointersMAIN RESULTS PageSectionAnalysisLineAnalysisPathAnalysisVT1.5AnalysisDS3Ana

Pagina 254

Menu MapsCTS 710 SONET Test Set User ManualA–23Zoom InZoom OutShowNext TopChangeTopChangeBottomHISTORY GRAPHS Page(History Resolution=Normal (1 min))1

Pagina 255

Menu MapsA–24CTS 710 SONET Test Set User ManualNameDescriptionSave To DiskSAVE RESULTS PageRESLT_XXClearEDIT NAMENoneClearEDIT TEXTSaveCurrentSavePrev

Pagina 256 - Setting the K2 Byte

Menu MapsCTS 710 SONET Test Set User ManualA–25Printer TypeRS–232Baud RateStop BitsParityFlow ControlPrinter User & CompanyUser NameCompany NamePR

Pagina 257

Getting StartedCTS 710 SONET Test Set User Manual1–3H CTS 710 SONET Test Set & CTS 750 SDH Test Set ServiceManual (Tektronix part number 070-8853-

Pagina 258

Menu MapsA–26CTS 710 SONET Test Set User ManualGPIB Primary AddressRS–232Baud RateStop BitsParityHardware HandshakeSoftware HandshakeData Carrier Dete

Pagina 259

Menu MapsCTS 710 SONET Test Set User ManualA–27Model:Serial Number:Hardware Revision:Option Revision:Firmware Revision:Options:Interface Module:DS1/DS

Pagina 260

Menu MapsA–28CTS 710 SONET Test Set User ManualMenu MapsA–28CTS 710 SONET Test Set User Manual

Pagina 261

CTS 710 SONET Test Set User ManualB–1Appendix B: Status and Error MessagesThis appendix describes the status and error messages that appear onthe CTS

Pagina 262 - The RECEIVE

Appendix B: Status and Error MessagesB–2CTS 710 SONET Test Set User ManualInstrument factory reset complete. The recall of default factorysettings, fr

Pagina 263 - Viewing Results

Appendix B: Status and Error MessagesCTS 710 SONET Test Set User ManualB–3Save of measurement results/histories complete. The CTS 710 hassuccessfully

Pagina 264 - Viewing Detailed Results

Appendix B: Status and Error MessagesB–4CTS 710 SONET Test Set User ManualCan not insert tributary error/alarm while adding external signal. Anattempt

Pagina 265

Appendix B: Status and Error MessagesCTS 710 SONET Test Set User ManualB–5Disk is full. You tried to save a file to disk and there is not enoughroom o

Pagina 266

Appendix B: Status and Error MessagesB–6CTS 710 SONET Test Set User Manualentered for the file to be saved to disk; that is, there is no default filen

Pagina 267

Appendix B: Status and Error MessagesCTS 710 SONET Test Set User ManualB–7Invalid history data format in file. You recalled a file that does notcontai

Pagina 268

Getting Started1–4CTS 710 SONET Test Set User ManualPouchPlateRearPanelTrimPouch PlateA. Push the pouch plate into the rear panel trim gap.Rear Panel

Pagina 269

Appendix B: Status and Error MessagesB–8CTS 710 SONET Test Set User ManualOperation invalid while a test is running. You tried to perform anaction tha

Pagina 270

CTS 710 SONET Test Set User ManualC–1Appendix C: Default Factory SettingsTable C–1 lists the instrument settings after Default Factory Settingshave be

Pagina 271 - Viewing Measurement Histories

Appendix C: Default Factory SettingsC–2CTS 710 SONET Test Set User ManualTable C–1: Default Factory Settings (Cont.)Parameter Default ValueReceive STS

Pagina 272

CTS 710 SONET Test Set User ManualD–1Appendix D: SpecificationsTable D–1: Standard CTS 710 Specifications Characteristic DescriptionGenerator OutputEl

Pagina 273

Appendix D: SpecificationsD–2CTS 710 SONET Test Set User ManualTable D–1: Standard CTS 710 Specifications (Cont.)Characteristic DescriptionSpectral Wi

Pagina 274 - VT Pointer Value

Appendix D: SpecificationsCTS 710 SONET Test Set User ManualD–3Table D–1: Standard CTS 710 Specifications (Cont.)Characteristic DescriptionAccuracy ±4

Pagina 275

Appendix D: SpecificationsD–4CTS 710 SONET Test Set User ManualTable D–1: Standard CTS 710 Specifications (Cont.)Characteristic DescriptionReturn Loss

Pagina 276

Appendix D: SpecificationsCTS 710 SONET Test Set User ManualD–5Table D–1: Standard CTS 710 Specifications (Cont.)Characteristic DescriptionPath Overhe

Pagina 277

Appendix D: SpecificationsD–6CTS 710 SONET Test Set User ManualTable D–1: Standard CTS 710 Specifications (Cont.)Characteristic DescriptionPhase trans

Pagina 278 - Zooming History Graphs

Appendix D: SpecificationsCTS 710 SONET Test Set User ManualD–7Table D–1: Standard CTS 710 Specifications (Cont.)Characteristic DescriptionPattern Bit

Pagina 279 - 60 minutes 12 hours

Getting StartedCTS 710 SONET Test Set User Manual1–5CAUTION. In the next step, use only enough force to clear the frontpanel trim with the plate front

Pagina 280 - Panning History Graphs

Appendix D: SpecificationsD–8CTS 710 SONET Test Set User ManualTable D–1: Standard CTS 710 Specifications (Cont.)Characteristic DescriptionAutoScan Au

Pagina 281

Appendix D: SpecificationsCTS 710 SONET Test Set User ManualD–9Table D–1: Standard CTS 710 Specifications (Cont.)Characteristic DescriptionHelp Mode O

Pagina 282 - Saving and Recalling Results

Appendix D: SpecificationsD–10CTS 710 SONET Test Set User ManualTable D–2: Option 22 DS1/DS3/VT1.5 Capabilities CharacteristicDescriptionDS1/DS3 Gener

Pagina 283

Appendix D: SpecificationsCTS 710 SONET Test Set User ManualD–11Table D–2: Option 22 DS1/DS3/VT1.5 Capabilities (Cont.)Characteristic DescriptionError

Pagina 284

Appendix D: SpecificationsD–12CTS 710 SONET Test Set User ManualTable D–2: Option 22 DS1/DS3/VT1.5 Capabilities (Cont.)Characteristic DescriptionExter

Pagina 285

Appendix D: SpecificationsCTS 710 SONET Test Set User ManualD–13Table D–2: Option 22 DS1/DS3/VT1.5 Capabilities (Cont.)Characteristic DescriptionDS1/D

Pagina 286 - Printing Results

Appendix D: SpecificationsD–14CTS 710 SONET Test Set User ManualTable D–2: Option 22 DS1/DS3/VT1.5 Capabilities (Cont.)Characteristic DescriptionVT Po

Pagina 287

Appendix D: SpecificationsCTS 710 SONET Test Set User ManualD–15Table D–2: Option 22 DS1/DS3/VT1.5 Capabilities (Cont.)Characteristic DescriptionPerio

Pagina 288

Appendix D: SpecificationsD–16CTS 710 SONET Test Set User ManualTable D–2: Option 22 DS1/DS3/VT1.5 Capabilities (Cont.)Characteristic DescriptionVT1.5

Pagina 289 - Changing Instrument Settings

Appendix D: SpecificationsCTS 710 SONET Test Set User ManualD–17Table D–2: Option 22 DS1/DS3/VT1.5 Capabilities (Cont.)Characteristic DescriptionHisto

Pagina 290

Getting Started1–6CTS 710 SONET Test Set User ManualDO NOT LIFTInstrumentWith D-RingFigure 1–3: Location of the D-Ring on the Accessory PouchGetting S

Pagina 291 - Turning the Beeper On and Off

Appendix D: SpecificationsD–18CTS 710 SONET Test Set User ManualTable D–4: Physical Characteristics CharacteristicDescriptionDimensions Height: 165 m

Pagina 292 - Setting the Time

Appendix D: SpecificationsCTS 710 SONET Test Set User ManualD–19Table D–5: Certifications and compliances (cont.)Characteristic DescriptionEC Declarat

Pagina 293 - Changing the Printer Setup

Appendix D: SpecificationsD–20CTS 710 SONET Test Set User ManualTable D–5: Certifications and compliances (cont.)Characteristic DescriptionInstallatio

Pagina 294

CTS 710 SONET Test Set User ManualE–1Appendix E: Incoming Inspection TestThe purpose of the incoming inspection test is to verify that theCTS 710 SONE

Pagina 295

Appendix E: Incoming Inspection TestE–2CTS 710 SONET Test Set User ManualTable E–1: Required Equipment Item Number and DescriptionMinimumRequirementsE

Pagina 296

Appendix E: Incoming Inspection TestCTS 710 SONET Test Set User ManualE–3How to ProceedIf the CTS 710 fails any of these tests, it has failed the inco

Pagina 297

Appendix E: Incoming Inspection TestE–4CTS 710 SONET Test Set User Manual2. Set up and execute the system self test with the followingsequence:Press M

Pagina 298

Appendix E: Incoming Inspection TestCTS 710 SONET Test Set User ManualE–52. Perform the initial setup of the CTS 710 with the followingsequence:Press

Pagina 299

Appendix E: Incoming Inspection TestE–6CTS 710 SONET Test Set User Manual7. To check the OC-3 rate, perform the setup sequence:Press MenuButtonSelect

Pagina 300 - Running Instrument Self Tests

Appendix E: Incoming Inspection TestCTS 710 SONET Test Set User ManualE–71. Attach electrical and optical loop-back cables from the OUToutputs to the

Pagina 301

Getting StartedCTS 710 SONET Test Set User Manual1–7Setting Up the CTS 710Before you use the CTS 710, ensure that it is properly set up andpowered on.

Pagina 302

Appendix E: Incoming Inspection TestE–8CTS 710 SONET Test Set User ManualAppendix E: Incoming Inspection TestE–8CTS 710 SONET Test Set User Manual

Pagina 303 - Appendices Appendices

CTS 710 SONET Test Set User ManualF–1Appendix F: Example Disk ContentsThis manual ships with a disk containing files that you can load intoyour CTS 71

Pagina 304

Appendix F: Example Disk ContentsF–2CTS 710 SONET Test Set User ManualThe BER_STS1 file is a 15-minute BER test. The test passes if theBER is better t

Pagina 305 - Appendix A: Menu Maps

CTS 710 SONET Test Set User ManualG–1Appendix G: Rear-Panel ConnectorsThis appendix describes the connectors located on the rear panel ofthe CTS 710.P

Pagina 306

Appendix G: Rear-Panel ConnectorsG–2CTS 710 SONET Test Set User ManualVGA connector. Table G–1 lists the pin assignment for the rear-panelVGA connecto

Pagina 307 - SAVE PASS/FAIL TESTS Page

Appendix G: Rear-Panel ConnectorsCTS 710 SONET Test Set User ManualG–3GPIB PortThe GPIB (General Purpose Interface Bus) port is used for remotecontrol

Pagina 308

Appendix G: Rear-Panel ConnectorsG–4CTS 710 SONET Test Set User ManualTable G–2: RS-232 Rear Panel Connector Pin Assignment (Cont.)Pin Number Descript

Pagina 309

Appendix G: Rear-Panel ConnectorsCTS 710 SONET Test Set User ManualG–5Overhead Add/Drop PortYou use the Overhead Add/Drop port to add/drop the section

Pagina 310

Appendix G: Rear-Panel ConnectorsG–6CTS 710 SONET Test Set User ManualTable G–4: Overhead Channels Dropped Dropped ChannelBytes Dropped Data Rate Clo

Pagina 311

Appendix G: Rear-Panel ConnectorsCTS 710 SONET Test Set User ManualG–7Table G–6: Overhead Add/Drop Port Additional PinAssignments Signal PinShield (gr

Pagina 312

Getting Started1–8CTS 710 SONET Test Set User ManualPowerConnectorPrincipalPower SwitchFuseGroundFigure 1–4: Rear-Panel Controls and Connectors Used i

Pagina 313

Appendix G: Rear-Panel ConnectorsG–8CTS 710 SONET Test Set User ManualAppendix G: Rear-Panel ConnectorsG–8CTS 710 SONET Test Set User Manual

Pagina 314

CTS 710 SONET Test Set User ManualH–1Appendix H: Changing Optical PortConnectorsThe following procedures are discussed in this appendix:H Cleaning the

Pagina 315

Appendix H: Changing Optical Port ConnectorsH–2CTS 710 SONET Test Set User ManualNOTE. To keep cleaning to a minimum, install the dustcap when nofiber

Pagina 316

Appendix H: Changing Optical Port ConnectorsCTS 710 SONET Test Set User ManualH–3Figure H–2: FC Optical Bulkhead AssemblyFigure H–3: ST Optical Bulkhe

Pagina 317

Appendix H: Changing Optical Port ConnectorsH–4CTS 710 SONET Test Set User ManualFigure H–4: DIN 47256 Optical Bulkhead AssemblyFigure H–5: SC Optical

Pagina 318 - APS COMMANDS Page (2 of 3)

CTS 710 SONET Test Set User ManualI–1Appendix I: Packing for ShipmentIf you ship the CTS 710, pack it in the original shipping carton andpacking mater

Pagina 319 - APS COMMANDS Page (3 of 3)

Appendix I: Packing for ShipmentI–2CTS 710 SONET Test Set User ManualAppendix I: Packing for ShipmentI–2CTS 710 SONET Test Set User Manual

Pagina 320

Glossary and Index Glossary and Index

Pagina 322

CTS 710 SONET Test Set User ManualGlossary–1GlossaryAISAn acronym for Alarm Indication Signal. An AIS is used to alertdownstream equipment that an ups

Pagina 323

Getting StartedCTS 710 SONET Test Set User Manual1–94. Check that you have the proper electrical connections. TheCTS 710 power requirements are listed

Pagina 324 - TRANSPORT OVERHEAD Page

GlossaryGlossary–2CTS 710 SONET Test Set User ManualCVAn acronym for Coding Violation.dBThe symbol for decibels.dBmThe symbol for power level in decib

Pagina 325

GlossaryCTS 710 SONET Test Set User ManualGlossary–3FEBEAn acronym for Far End Block Error. An indication returned tothe transmitting LTE that an erro

Pagina 326 - ERROR ANALYSIS Page

GlossaryGlossary–4CTS 710 SONET Test Set User ManualLine Severely Errored Second (SES)A second with N or more Line CVs, or a second during whichthe li

Pagina 327

GlossaryCTS 710 SONET Test Set User ManualGlossary–5status and maintenance information between two networkelements.POHAn acronym for Path Overhead.PTE

Pagina 328

GlossaryGlossary–6CTS 710 SONET Test Set User ManualSONETAn acronym for Synchronous Optical NETwork.SPEAn acronym for Synchronous Payload Envelope.STE

Pagina 329 - PRINTER SETUP Page

GlossaryCTS 710 SONET Test Set User ManualGlossary–7Through ModeThe ability to retransmit the incoming signal and manipulate itscontents.TOHAn acronym

Pagina 330 - REMOTE CONTROL Page

GlossaryGlossary–8CTS 710 SONET Test Set User ManualGlossaryGlossary–8CTS 710 SONET Test Set User Manual

Pagina 331 - SELF TEST Page

CTS 710 SONET Test Set User ManualIndex–1IndexAAbortPRINT CONTROL dialog box,3–197, 3–198Self Test Control, 3–211accessoriesoptional, 1–2standard, 1–2

Pagina 332

IndexIndex–2CTS 710 SONET Test Set User ManualChannel Requesting, APS COM-MANDS, 3–165, 3–167checkingAPS response, 3–161continuity, 3–2error and alarm

Pagina 333 - Status Messages

IndexCTS 710 SONET Test Set User ManualIndex–3Default (XXXXXXXX), TRANS-PORT OVERHEAD, 3–79Default 0ppm, Frequency Offset,3–150Default 4, GPIB Primary

Pagina 335 - Error Messages

Getting Started1–10CTS 710 SONET Test Set User ManualON/STBYButtonFigure 1–5: ON/STBY ButtonThe CTS 710 performs an internal self test each time it is

Pagina 336

IndexIndex–4CTS 710 SONET Test Set User ManualDS1 SF (D4)DS1 Framing, 3–108, 3–128Framing, 3–94, 3–125Payload, 3–74, 3–111DS1 UnframedDS1 Framing, 3–1

Pagina 337

IndexCTS 710 SONET Test Set User ManualIndex–5Error Ratio, Fail If condition, 3–39Error type set to, ERRORS &ALARMS, 3–132Errored Seconds, Fail If

Pagina 338

IndexIndex–6CTS 710 SONET Test Set User ManualHHardware Handshake, REMOTECONTROL, 3–209Hardware Revision, INSTR CON-FIG, 3–199HELP button, 2–12Help di

Pagina 339

IndexCTS 710 SONET Test Set User ManualIndex–7LINE FERF, status light, 3–60Line FERF, Transmit alarm set to,3–136line rate, 3–64, 3–90LOFFailure set t

Pagina 340

IndexIndex–8CTS 710 SONET Test Set User ManualNo Mapping (Unequipped), Map-ping, 3–71, 3–72NoneDescriptionSAVE PASS/FAIL TESTS,3–45SAVE RESULTS, 3–193

Pagina 341

IndexCTS 710 SONET Test Set User ManualIndex–9Path FERF, Transmit alarm set to,3–136Path Overhead, viewing, 3–80,3–116, 3–117path overhead bytes, sett

Pagina 342

IndexIndex–10CTS 710 SONET Test Set User Manualprinter setup, 3–203Printer Type, PRINTER SETUP,3–204printersRS–232 parameters, 3–204supported, 3–204pr

Pagina 343 - Appendix D: Specifications

IndexCTS 710 SONET Test Set User ManualIndex–11Save to DiskOn Test Completion, 3–49SAVE INSTRUMENT SETUPS,3–34SAVE RESULTS, 3–194Save to Memory, SAVE

Pagina 344

IndexIndex–12CTS 710 SONET Test Set User ManualSTS-1, Signal Structure, RECEIVESETTINGS, 3–104STS-3c, Signal Structure, RE-CEIVE SETTINGS, 3–104symbol

Pagina 345

IndexCTS 710 SONET Test Set User ManualIndex–13Tx/Rx Settings line, RECEIVESETTINGS page, 3–101UUnknown, Test Pattern, 3–129RECEIVE SETTINGS, 3–109,3–

Pagina 346

Operating Basics Operating Basics

Pagina 347

IndexIndex–14CTS 710 SONET Test Set User ManualYyellow lights, 2–5, 3–60Z0. DEFAULT memory, RECALLINSTRUMENT SETUPS page,3–35Zoom In, HISTORY GRAPHS,3

Pagina 349

CTS 710 SONET Test Set User Manual2–1Functional OverviewThis section describes how to use and navigate through the basicfunctions of the CTS 710, incl

Pagina 350

Functional Overview2–2CTS 710 SONET Test Set User ManualFront-Panel Controls, Indicators, and ConnectorsFigures 2–1 and 2–2 identify the controls, ind

Pagina 351

Functional OverviewCTS 710 SONET Test Set User Manual2–3ElectricalConnectorsOpticalConnectorDisk DriveLASER INUSE IndicatorStatus LightsEach of these

Pagina 352

Functional Overview2–4CTS 710 SONET Test Set User ManualRear-Panel Controls and ConnectorsPowerConnectorPrincipalPowerSwitchFuseVGAVideoOutputGPIBPort

Pagina 353

Functional OverviewCTS 710 SONET Test Set User Manual2–5H Yellow history lights. Once an event has been detected, a yellowhistory light is turned on.

Pagina 354

Functional Overview2–6CTS 710 SONET Test Set User ManualReading the DisplayThere are several major areas that make up the CTS 710 display (seeFigure 2

Pagina 355

Functional OverviewCTS 710 SONET Test Set User Manual2–7Figure 2–6 provides a guide to specific areas of the display.MenuNameTest StateIndicatorHighli

Pagina 356

CTS 710 SONET Test Set User ManualiTable of ContentsGeneral Safety Summary xvii. . . . . . . . . . . . . . . . . . . . . . . . . . . . Preface xxi. .

Pagina 357

Functional Overview2–8CTS 710 SONET Test Set User ManualTable 2–1: Icons that Appear in the Display IconMeaningTransmitted signalReceived signalCTS 71

Pagina 358

Functional OverviewCTS 710 SONET Test Set User Manual2–9The Basic Menu StructureThe CTS 710 is controlled primarily through its menu system.Though sev

Pagina 359

Functional Overview2–10CTS 710 SONET Test Set User Manualidentified by a page tab located at the bottom of the display (seeFigure 2–8).RECEIVESETTINGS

Pagina 360

Functional OverviewCTS 710 SONET Test Set User Manual2–11NOTE. The only times pressing a menu button does not change menusare when a dialog box is dis

Pagina 361

Functional Overview2–12CTS 710 SONET Test Set User ManualDisplay the page bypressing the buttonbelow the page tab.Page TabFigure 2–10: How to Display

Pagina 362

Functional OverviewCTS 710 SONET Test Set User Manual2–13Figure 2–11: Help Dialog BoxOnce you press View Help, the help screen for that topic isdispla

Pagina 363

Functional Overview2–14CTS 710 SONET Test Set User ManualConnecting Optical SignalsNOTE. The optical TRANSMIT output is produced by a Class 1 laserdev

Pagina 364 - Loop-Back Connection

Functional OverviewCTS 710 SONET Test Set User Manual2–15Connecting SONET Electrical SignalsTo connect SONET electrical signals to the CTS 710:1. Conn

Pagina 365 - How to Proceed

Functional Overview2–16CTS 710 SONET Test Set User ManualSelecting ParametersTo change a parameter, use the knob to highlight it. As you turn theknob,

Pagina 366 - SONET Signals

Functional OverviewCTS 710 SONET Test Set User Manual2–17you press –more– the next list of choices is displayed. Below –more–is a line that shows whic

Pagina 367

Table of ContentsiiCTS 710 SONET Test Set User ManualChanging Parameters 2–15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Selecti

Pagina 368

Functional Overview2–18CTS 710 SONET Test Set User ManualSelecting USERDEFINED allows you toenter a numeric value.Figure 2–14: Selecting USER DEFINEDA

Pagina 369

Functional OverviewCTS 710 SONET Test Set User Manual2–19Selecting this choice allows the knobto make large changes quickly.Selecting thischoice allow

Pagina 370

Functional Overview2–20CTS 710 SONET Test Set User ManualChanging Binary NumbersThere are two kinds of binary numbers that can be changed in theCTS 71

Pagina 371

Functional OverviewCTS 710 SONET Test Set User Manual2–213. To change the value of the highlighted bit, select either 1 or 0.Each time you select 1 or

Pagina 372

Functional Overview2–22CTS 710 SONET Test Set User ManualSelect the text string to edit byusing the knob.Select EDIT TEXT toedit the specifiedtext str

Pagina 373 - VGA Video Output

Functional OverviewCTS 710 SONET Test Set User Manual2–235. When you are finished editing the text string, select DONE.The characters available depend

Pagina 374

Functional Overview2–24CTS 710 SONET Test Set User ManualTable 2–2: CTS 710 Disk File Types File TypeDescription File ExtensionInstrument Setups Compl

Pagina 375 - GPIB Port

Functional OverviewCTS 710 SONET Test Set User Manual2–252. Press the TEST SETUPS front-panel button to display the TESTSETUPS menu.3. Select the RECA

Pagina 376 - Calibration Signal Output

Functional Overview2–26CTS 710 SONET Test Set User ManualFunctional Overview2–26CTS 710 SONET Test Set User Manual

Pagina 377 - Overhead Add/Drop Port

CTS 710 SONET Test Set User Manual2–27TutorialThe tutorial acquaints you with the features of the CTS 710 byhaving you run a test while you explore sp

Pagina 378

Table of ContentsCTS 710 SONET Test Set User ManualiiiStarting and Stopping a Test 3–27. . . . . . . . . . . . . . . . . . . . . . . . . . . Making Ch

Pagina 379 - BITS Timing Reference Input

Tutorial2–28CTS 710 SONET Test Set User ManualConnect the coaxial cable between the TRANSMIT and RECEIVEBNC connectors on the front panel (see Figure

Pagina 380

TutorialCTS 710 SONET Test Set User Manual2–29To set the transmit and receive parameters:Press MenuButtonSelect MenuPageHighlightParameterSelect Choic

Pagina 381 - Connectors

Tutorial2–30CTS 710 SONET Test Set User ManualTo specify which signal, or STS, to test:Press MenuButtonSelect MenuPageHighlightParameterSelect ChoiceS

Pagina 382

TutorialCTS 710 SONET Test Set User Manual2–31coupled. However, note that the yellow history light remains on as anindication that an error has occurr

Pagina 383

Tutorial2–32CTS 710 SONET Test Set User ManualWhere Test Results Are DisplayedOnce you have set the transmit and receive parameters and the testtime,

Pagina 384

TutorialCTS 710 SONET Test Set User Manual2–33The RESULTS menu contains four pages on which results aredisplayed: TEST SUMMARY, MAIN RESULTS, ERRORANA

Pagina 385

Tutorial2–34CTS 710 SONET Test Set User ManualThere are two elements to the test status indicator. The text above thebar graph indicates how long the

Pagina 386

TutorialCTS 710 SONET Test Set User Manual2–35Figure 2–26: The ERRORS & ALARMS Page of the TRANSMIT MenuThere are two ways to insert errors into t

Pagina 387

Tutorial2–36CTS 710 SONET Test Set User Manualthan None results in a continuous stream of errors being inserted intothe transmitted signal.To insert a

Pagina 388

TutorialCTS 710 SONET Test Set User Manual2–37To display the POINTERS & TIMING page:Press MenuButtonSelect MenuPageHighlightParameterSelect Choice

Pagina 389 - Glossary

Table of ContentsivCTS 710 SONET Test Set User ManualMapping a Tributary Signal (Add/Drop/Test Option Only) 3–72. . . Mapping a Tributary with VT1.5 F

Pagina 390

Tutorial2–38CTS 710 SONET Test Set User ManualAfter selecting Single for pointer control, a message displays thattells you how to adjust the pointer.

Pagina 391

TutorialCTS 710 SONET Test Set User Manual2–39If the preset choices do not match what you need, use USERDEFINED to define an alternative.To define a s

Pagina 392

Tutorial2–40CTS 710 SONET Test Set User ManualUse the knob to change the value of Frequency Offset; select anyvalue you wish. When you are finished se

Pagina 393

TutorialCTS 710 SONET Test Set User Manual2–41Figure 2–29: The TRANSPORT OVERHEAD Page of the TRANSMITMenuThe Showing Overhead for parameter identifie

Pagina 394 - SONET Signal Hierarchy

Tutorial2–42CTS 710 SONET Test Set User ManualTo edit a byte of the transport overhead:Press MenuButtonSelect MenuPageHighlightParameterSelect ChoiceS

Pagina 395

TutorialCTS 710 SONET Test Set User Manual2–43have selected Set to 10101010. To see that the CTS 710 is nowreceiving the new value of the S1 byte:Pres

Pagina 396

Tutorial2–44CTS 710 SONET Test Set User ManualFigure 2–31: The TEST SUMMARY Page of the RESULTS MenuThe MAIN RESULTS page displays all the errors that

Pagina 397

TutorialCTS 710 SONET Test Set User Manual2–45Figure 2–32: The MAIN RESULTS Page of the RESULTS MenuThis completes the tutorial. For detailed informat

Pagina 398

Tutorial2–46CTS 710 SONET Test Set User ManualTutorial2–46CTS 710 SONET Test Set User Manual

Pagina 399

Reference Reference

Pagina 400

Table of ContentsCTS 710 SONET Test Set User ManualvViewing Overhead Bytes 3–115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Viewing Tr

Pagina 402

CTS 710 SONET Test Set User Manual3–1Basic Test ProceduresThis section gives examples of how to set up and use theCTS 710 SONET Test Set for several c

Pagina 403

Basic Test Procedures3–2CTS 710 SONET Test Set User Manual Network Continuity CheckingWith the AUTOSCAN feature of the CTS 710, it is easy to make aqu

Pagina 404

Basic Test ProceduresCTS 710 SONET Test Set User Manual3–32. Set up the CTS 710 as follows:Press MenuButtonSelect MenuPageHighlightParameterSelect Cho

Pagina 405

Basic Test Procedures3–4CTS 710 SONET Test Set User ManualTransmission Signal Quality TestingMeasuring Bit Error RateThe bit error rate (BER) test is

Pagina 406

Basic Test ProceduresCTS 710 SONET Test Set User Manual3–52. Set up the CTS 710 as follows:Press MenuButtonSelect MenuPageHighlightParameterSelect Cho

Pagina 407

Basic Test Procedures3–6CTS 710 SONET Test Set User Manual8. If you wish, you can also enter a description of the test results byhighlighting Descript

Pagina 408

Basic Test ProceduresCTS 710 SONET Test Set User Manual3–72. Set up the CTS 710 as follows:Press MenuButtonSelect MenuPageHighlightParameterSelect Cho

Pagina 409

Basic Test Procedures3–8CTS 710 SONET Test Set User Manual4. When the test is complete, you can store the test results to disk orprint out a hardcopy.

Pagina 410

Basic Test ProceduresCTS 710 SONET Test Set User Manual3–9connecting the upstream and downstream signals to the RECEIVEinput.Table 3–1 shows the respo

Comentarios a estos manuales

Sin comentarios