Pagina 1 - 071-1187-01

User ManualP72252.5 GHz 10X Active Probe071-1187-01WarningThe servicing instructions are for use by qualifiedpersonnel only. To avoid personal injury,

Pagina 2

General Safety SummaryviP7225 2.5 GHz 10X Active Probe User ManualSafety Terms and SymbolsTerms in This Manual. These terms may appear in this manual:

Pagina 3 - WARRANTY

P7225 2.5 GHz 10X Active Probe User ManualviiPrefaceThis is the User Manual for the P7225 probe. This manual providesoperating information, specificat

Pagina 4

PrefaceviiiP7225 2.5 GHz 10X Active Probe User ManualContacting TektronixPhone 1-800-833-9200*Address Tektronix, Inc.Department or name (if known)1420

Pagina 5 - Table of Contents

P7225 2.5 GHz 10X Active Probe User Manual1Product DescriptionThe Tektronix P7225 is a 2.5 GHz, 10X active probe. The P7225 hasa ≤0.8 pF input capacit

Pagina 6 - List of Figures

Product Description2P7225 2.5 GHz 10X Active Probe User ManualWhen the probe is connected, the host i nstrument reads EEPROMinformation from the probe

Pagina 7 - List of Tables

Product DescriptionP7225 2.5 GHz 10X Active Probe User Manual3OptionsThe following options are available when orderi ng the P7225 probe:H Option D1 —

Pagina 8

Product Description4P7225 2.5 GHz 10X Active Probe User Manual

Pagina 9 - General Safety Summary

P7225 2.5 GHz 10X Active Probe User Manual5Features and Accesso riesThe P7225 is provided with several features and accessories designedto make probin

Pagina 10 - Safety Terms and Symbols

Features and Accessories6P7225 2.5 GHz 10X Active Probe User ManualTable 1: P7225 features and standard accessories (Cont.)Feature/Accessory Descripti

Pagina 11 - Related Manuals

Features and AccessoriesP7225 2.5 GHz 10X Active Probe User Manual7Table 1: P7225 features and standard accessories (Cont.)Feature/Accessory Descripti

Pagina 12 - Contacting Tektronix

Copyright © Tektronix, Inc. All rights reserved.Tektronix products are covered by U.S. and foreign patents, issued andpending. Information in this pub

Pagina 13 - Product Description

Features and Accessories8P7225 2.5 GHz 10X Active Probe User ManualTable 1: P7225 features and standard accessories (Cont.)Feature/Accessory Descripti

Pagina 14 - Installation

Features and AccessoriesP7225 2.5 GHz 10X Active Probe User Manual9Table 1: P7225 features and standard accessories (Cont.)Feature/Accessory Descripti

Pagina 15

Features and Accessories10P7225 2.5 GHz 10X Active Probe User ManualTable 1: P7225 features and standard accessories (Cont.)Feature/Accessory Descript

Pagina 16

Features and AccessoriesP7225 2.5 GHz 10X Active Probe User Manual11Table 1: P7225 features and standard accessories (Cont.)Feature/Accessory Descript

Pagina 17 - Features and Accesso ries

Features and Accessories12P7225 2.5 GHz 10X Active Probe User ManualTable 2 lists the optional acce ssories you can order for your P7225probe.Table 2:

Pagina 18 - Features and Accessories

Features and AccessoriesP7225 2.5 GHz 10X Active Probe User Manual13Table 2: P7225 optional accessories (Cont.)Accessory DescriptionTekConnect Interfa

Pagina 19

Features and Accessories14P7225 2.5 GHz 10X Active Probe User ManualTable 2: P7225 optional accessories (Cont.)Accessory DescriptionProbe Calibration

Pagina 20 - . Use the adapter spring for

P7225 2.5 GHz 10X Active Probe User Manual15Functional CheckA functional check may be performed using the PROBE COM-PENSATION connections on the front

Pagina 21 - Y-lead adapter

Functional Check16P7225 2.5 GHz 10X Active Probe User Manual3. Using a ground lead and SMT KlipChip, connect the probeground to the instrument ground

Pagina 22 - . Attach matching pairs of

P7225 2.5 GHz 10X Active Probe User Manual17ConfigurationThe P7225 provides the host instrument with the probe modelnumber, serial number, and att enu

Pagina 23

WARRANTYTektronix warrants that the systems that it manufactures and sells, (excludingcustomer-supplied equipment), will be free from defects in mater

Pagina 24

Configuration18P7225 2.5 GHz 10X Active Probe User Manual6. Change the volts/division setting to the desired range, adjustingthe offset to keep the tr

Pagina 25

P7225 2.5 GHz 10X Active Probe User Manual19Operating BasicsPlease follow these operating guidelines to get optimum performancefrom your P7225 probe.H

Pagina 26

Operating Basics20P7225 2.5 GHz 10X Active Probe User ManualInput Linear Dynamic RangeThe probe head amplifier used by the P7225 has a limited linearo

Pagina 27 - Functional Check

Operating BasicsP7225 2.5 GHz 10X Active Probe User Manual211.7 in Y lead adapter with 2 SMT KlipChipsProbe with only short ground pogo pinTest pulse

Pagina 28

Operating Basics22P7225 2.5 GHz 10X Active Probe User ManualTest pulse without probeProbe with only short ground pogo pinSquare pins on test board (no

Pagina 29 - Configuration

Operating BasicsP7225 2.5 GHz 10X Active Probe User Manual23VsourceProbe Cin≤0.8 pFLgl(ground lead)Figure 7: Ground lead equivalent circuitRinging and

Pagina 30

Operating Basics24P7225 2.5 GHz 10X Active Probe User Manual

Pagina 31 - Operating Basics

P7225 2.5 GHz 10X Active Probe User Manual25Helpful HintsFollow these helpful hints to make probing easier and noise free.Low-inductance GroundingPlac

Pagina 32 - Input Linear Dynamic Range

Helpful Hints26P7225 2.5 GHz 10X Active Probe User ManualThis method is very useful when making many measurements on thesame package. Using a ground p

Pagina 33 - Ground Lead Length

Helpful HintsP7225 2.5 GHz 10X Active Probe User Manual27Probe Tip Test PointsYou can solder the push-in probe tip or a 0.025 i nch square pin to acir

Pagina 35 - (ground lead)

Helpful Hints28P7225 2.5 GHz 10X Active Probe User Manual

Pagina 36

P7225 2.5 GHz 10X Active Probe User Manual29Appendix A: SpecificationsThe probe and host instrument must first be allowed to warm up for20 minutes bef

Pagina 37 - Helpful Hints

Appendix A: Specifications30P7225 2.5 GHz 10X Active Probe User ManualTable 4: Typical electrical characteristics (Cont.)Linearity ᐔ0.1% over a dynami

Pagina 38 - SureFoot Grounding

Appendix A: SpecificationsP7225 2.5 GHz 10X Active Probe User Manual3145 KΩ110 °40 KΩ35 KΩ30 KΩ25 KΩ1 MHz 10 MHz 100 MHz 1 GHz 10 GHz90 °70 °50 °30 °1

Pagina 39 - Probe Tip Test Points

Appendix A: Specifications32P7225 2.5 GHz 10X Active Probe User ManualFrequency100 MHz10 MHz 10 GHz1GHz-- 1 7-- 2 0-- 2 3-- 2 6-- 2 9-- 3 2Gain = 20 L

Pagina 40

Appendix A: SpecificationsP7225 2.5 GHz 10X Active Probe User Manual3331.8 mm(1.250 in)43.8 mm(1.725 in)63.5 mm(2.500 in)91.5 mm(3.600 in)57.2 mm(2.25

Pagina 41 - Appendix A: Specifications

Appendix A: Specifications34P7225 2.5 GHz 10X Active Probe User ManualTable 7: Certifications and compliancesCategory Standards or descriptionEMC comp

Pagina 42

P7225 2.5 GHz 10X Active Probe User Manual35Appendix B: User ServiceThis section explains the mainte nance for the P7225 probe.Inspection and Cleaning

Pagina 43

Appendix B: User Service36P7225 2.5 GHz 10X Active Probe User ManualPreparation for ShipmentIf the original packaging is unfit for use or not availabl

Pagina 44

P7225 2.5 GHz 10X Active Probe User Manual37Appendix C: Replaceable PartsThis section contains a list of replaceable parts for the P7225 probe.Use thi

Pagina 45

P7225 2.5 GHz 10X Active Probe User ManualiTable of ContentsGeneral Safety Summary v...Preface vii...

Pagina 46

Appendix C: Replaceable Parts38P7225 2.5 GHz 10X Active Probe User ManualUsing the Replaceable Parts ListThe tabular information in the Replaceable Pa

Pagina 47 - Appendix B: User Service

Appendix C: Replaceable PartsP7225 2.5 GHz 10X Active Probe User Manual3912Figure 14: P7225 replaceable partsFig. &index no.Tektronixpart no.Seria

Pagina 48 - Preparation for Shipment

Appendix C: Replaceable PartsP7225 2.5 GHz 10X Active Probe User Manual401 234567 8 9101112Figure 15: P7225 standard accessories

Pagina 49 - Appendix C: Replaceable Parts

Appendix C: Replaceable PartsP7225 2.5 GHz 10X Active Probe User Manual41Fig. &index no.Tektronixpart no.Serial no.Effective DscontQty12345 name &

Pagina 50

Appendix C: Replaceable PartsP7225 2.5 GHz 10X Active Probe User Manual4212345678Figure 16: P7225 optional accessories

Pagina 51

Appendix C: Replaceable PartsP7225 2.5 GHz 10X Active Probe User Manual43Fig. &index no.Tektronixpart no.Serial no.Effective DscontQty12345 name &

Pagina 52

Appendix C: Replaceable PartsP7225 2.5 GHz 10X Active Probe User Manual44CROSS INDEX - MFR. CODE NUMBER TO MANUFACTURERMfr. code Manufacturer Address

Pagina 53

Table of ContentsiiP7225 2.5 GHz 10X Active Probe User ManualList of FiguresFigure 1: P7225 Probe featuring the TekConnect Interface 1Figure 2: Connec

Pagina 54

Table of ContentsP7225 2.5 GHz 10X Active Probe User ManualiiiList of TablesTable 1: P7225 features and standard accessories 5...Table 2: P7225 o

Pagina 55

Table of ContentsivP7225 2.5 GHz 10X Active Probe User Manual

Pagina 56

P7225 2.5 GHz 10X Active Probe User ManualvGeneral Safety SummaryReview the following safety precaut ions to avoid injury and preventdamage to this pr

Comentarios a estos manuales