Tektronix AFG3000 Manual de usuario Pagina 158

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 230
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 157
Syntax and Commands
3-84 AFG3000 Series Arbitrary/Function Generators Reference Manual
[SOURce[1|2]]:VOLTage[:LEVel][:IMMediate]:OFFSet
This command sets or queries the offset level for the specified channel. If your
instrument is a dual-channel model and the [SOURce[1|2]]:VOLTage:CONCur-
rent[:STATe] command is set to ON, then the offset level of the other channel is
also the same value.
Group
Source
Related Commands
[SOURce[1|2]]:VOLTage:CONCurrent[:STATe]
Syntax
[SOURce[1|2]]:VOLTage[:LEVel][:IMMediate]:OFFSet{<voltage>
|MINimum|MAXimum}
[SOURce[1|2]]:VOLTage[:LEVel][:IMMediate]:OFFSet?{MINimum|
MAXimum}
Arguments
<voltage>::=<NRf>[<units>]
where
<NRf> is the offset voltage level.
<units>::=[mV | V]
Returns
<voltage>
Examples
SOURce1:VOLTage:LEVel:IMMediate:OFFSet 500mV
sets the CH 1 offset level to 500 mV.
Vista de pagina 157
1 2 ... 153 154 155 156 157 158 159 160 161 162 163 ... 229 230

Comentarios a estos manuales

Sin comentarios