The Graphical Waveform Editor
3-70 AWG710&AWG710B Arbitrary Waveform Generator User Manual
The Import Pattern function lets you read waveform or pattern data from the
specified target data type of the active window and stores it in the pattern buffer.
You can then replace waveform or marker data with the pattern data in the current
window or another window. The Set Pattern dialog box converts all waveform data
greater than 0.5 volts to a one level if the waveform data is analog T. All waveform
data less than or equal to 0.5 volts is set to a zero level.
Do the following steps to use the Import Pattern function to convert waveform data
into pattern data:
1. Move the cursors to specify the edit area from which to import the waveform
pattern data.
2. Push Operation (bottom)!Set Pattern... (pop–up)!OK (side).
The Set Pattern dialog box appears.
3. Select Data, Marker1, or Marker2 to specify the data type from which to
import the pattern data.
4. Push the Import Pattern side button to import the pattern data.
All waveform data above 0.5 becomes a one pattern value, and all waveform
data at or below 0.5 becomes a zero pattern value. The pattern data is stored in
the pattern buffer.
5. Select Data, Marker1, or Marker2 to specify the data type to replace with the
pattern data.
6. Push the OK side button to replace the waveform or marker data with the
specified pattern data.
Do the following steps to write pattern data between different editor windows:
1. Move the cursors to specify the edit area from which to import the waveform
pattern data.
2. Push Operation (bottom)!Set Pattern... (pop–up)!OK (side).
The Set Pattern dialog box appears.
3. Select Data, Marker1, or Marker2 to specify the data type from which to
import the pattern data.
4. Push the Import Pattern side button to import the pattern data.
All waveform data above 0.5 becomes a one pattern value, and all waveform
data at or below 0.5 becomes a zero pattern value. The pattern data is stored in
the pattern buffer.
Vista de pagina 199
1 2 ... 195 196 197 198 199 200 201 202 203 204 205 ... 579 580

Comentarios a estos manuales

Sin comentarios

Jenway Genova Plus French manuels

Manuels d'utilisation et guides de l'utilisateur pour Équipement Jenway Genova Plus French.
Nous fournissons des manuels en pdf 1 Jenway Genova Plus French à télécharger gratuitement par type de document : Manuel de l'utilisateur






Plus de produits et de manuels pour Équipement Jenway

Modèles Type de document
Genova Plus German Manuel de l'utilisateur   Jenway Genova Plus German Benutzerhandbuch, 116 pages
6715 Manuel de l'utilisateur   Jenway 6715 User Manual, 181 pages