Programming Examples
AWG710&AWG710B Arbitrary Waveform Generator User Manual 3-213
Figure 3-68: Noise waveforms after filtering
Example 6
The following example shows a code conversion. In this example, two kinds of
data are created with data() function. You need to prepare the code conversion
tables which can be created with the text editor or Code Convert Table dialog box.
The Code Convert Table dialog box is brought up by pushing Tools
(bottom)!Code Convert... (pop–up)!
OK (side)!Edit... (side) from the waveform or pattern editor.
"C0.WFM" = data(0, 1, 0, 0, 1, 1, 0, 0, 0)
"C1.WFM" = code("C0.WFM", "nrz.txt")
"C2.WFM" = code("C0.WFM", "nrzi.txt")
"C3.WFM" = code("C0.WFM", "nrzi-2.txt")
"C4.WFM" = code("C0.WFM", "fm.txt")
"C5.WFM" = code("C0.WFM", "bi-phase.txt")
"C6.WFM" = code("C0.WFM", "rz.txt")
"C7.WFM" = code("C0.WFM", "special.txt")
"C0.WFM" = data(0,1,1,0,1,1,0,0,1,0,1,0,0,0,1,1,1,1,0,
0,0,1,0,0,1,1,1,0,0,0,0,0)
"C8.WFM" = code("C0.WFM", "1-7rill.txt")
NOISE.WFM N1.WFM–(after LPF) N2.WFM–(after HPF)
N3.WFM–(after BPF) N4.WFM–(after BRF)