Commands Listed in Alphabetical Order
POWer:QUALit
y:DISplay:TRUEpwr
Sets or returns the display state for the true power readout.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:QUALity:DISplay:TRUE pwr {OFF|ON|0|1}
POWer:QUALity:DISplay:TRUE pwr?
Arguments
OFF or 0 turns off the true power display.
ON or 1 turns on the true power display.
Examples
POWER:QUALITY:DISPLAY:TRUE PWR 1 turns on the true power display.
POWER:QUALITY:DISPLAY:TRUE PWR? might return
:POWER:QUALITY:DISPLAY:TRU EPWR 0 indicating that the true power
display is off.
POWer:QUALity:DISplay:VCRESTfactor
Sets or returns the display state for the voltage crest factor readout.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:QUALity:DISplay:VCRE STfactor {OFF|ON|0|1}
POWer:QUALity:DISplay:VCRE STfactor?
Arguments
OFF or 0 turns off the voltage crest factor display.
ON or 1 turns on the voltage crest factor display.
Examples
POWER:QUALITY:DISPLAY:VCRE STFACTOR 1 turns on the voltage crest factor
display.