Tektronix DPO4000 Manual de usuario Pagina 296

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 585
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 295
Commands Listed in Alphabetical Order
POWer:RIPPle
:RESults:MEAN? (Query Only)
Returns the mean of the peak-to-peak ripple measurements.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:RIPPle:RESults:MEAN ?
Examples
POWER:RIPPLE:RESULTS:MEAN ? might return
:POWER:RIPPLE:RESULTS:MEA N 1.0 indicating that the mean peak-to-peak
amplitude is set to 1.0 V.
POWer:RIPPle:RESults:MIN? (Query Only)
Returns the minimum of the peak-to-peak ripple measurement.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:RIPPle:RESults:MIN?
Examples
POWER:RIPPLE:RESULTS:MIN? might return :POWER:RIPPLE:RESULTS:MIN
0.9
indicating that the minimum peak-to-peak amplitude is set to 0.9 V.
POWer:RIPPle:RESults:STDdev? (Query Only)
Returns the standard deviation o f the peak-to-peak ripple measurements.
Conditions
T
his command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:RIPPle:RESults:STDd ev?
2-286 MSO4000 and DPO4000 Series Programmer Manual
Vista de pagina 295
1 2 ... 291 292 293 294 295 296 297 298 299 300 301 ... 584 585

Comentarios a estos manuales

Sin comentarios