Commands Listed in Alphabetical Order
Examples
POWER:SOA:LIN
EAR:YMAX 700
sets the YMAX value to 700.0000.
POWER:SOA:LINEAR:YMAX ? might return :POWER:SO A:LINear:YMAX
50.0000
indic
ating that the YMAX value for linear plot type is set to 50.0000.
POWer:SOA:LINear:YMIN
Sets or returns the user YMIN value for use in linear SOA calculations.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:SOA:LINear:YMIN <NR3>
POWer:SOA:LINear:YMIN?
Arguments
<NR3> is the YMIN value used for linear SOA calculations.
Examples
POWER:SOA:LINEAR:YMIN 2 sets the YMIN value to 2.0000.
POWER:SOA:LINEAR:YMIN ? might return :POWER:SO A:LINear:YMIN
0.0E+0
indicating that the YMIN value for linear plot type is set to 0.0E+0.
POWer:SOA:LOG:XMAX
Sets or returns the user XMAX value for use in Log SOA calculations.
Conditions
This command requires a DPO4PWR application module.
Group
Power
Syntax
POWer:SOA:LOG:XMAX <NR3>
POWer:SOA:LOG:XMAX?
Arguments
<NR3> is the XMAX value used for log SOA calculations.
MSO4000 and DPO4000 Series Programmer Manual 2-289